Skip to main content
Siemens 3RV2032-4VA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2032-4VA15 SIRIUS Motor Protection Circuit Breake

MPN3RV2032-4VA15
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2032-4VA15, 45 A rated at 480/600 V, 50 kA breaking capacity at 400 V, CLASS 10 trip, screw and snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2032-4VA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2032-4VA15 — Electrical
ParameterValue
Rated operational current (Ie)45 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)24.5 W
Power loss, per pole (AC, hot)8.2 W
3RV2032-4VA15 — Protection & Tripping
ParameterValue
Overload release setting range35 ... 45 A
Instantaneous short-circuit trip current650 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)15 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2032-4VA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2032-4VA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 1)
3RV2032-4VA15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2032-4VA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2032-4VA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

Rated 45 A continuous at both 480 V and 600 V, it covers the common North American motor full-load current range up to a 30 hp at 480 V or a 40 hp at 600 V. Trip class is CLASS 10, so it clears an overload in under 10 seconds at 600% of the thermal setting. That matches the standard starting profile of a NEMA Design B motor — the breaker holds through the inrush but trips before the winding reaches its thermal limit on a stalled rotor.

Mounting and clearance for a retrofit or new panel

Dimensions: 55 mm wide, 140 mm tall, 149 mm deep. The 55 mm width is three 18 mm module widths — a standard footprint for a SIRIUS motor-protective device. Any mounting position works, so it can go sideways in a tight gland-plate zone if the vertical clearance is tight. Terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded copper. Main contact torque is M6 — standard for this current class.

Frequently asked questions

What is 3RV2032-4VA15's listed depth (149 mm) on this component line?

The depth is 149 mm, with a width of 55 mm and a height of 140 mm.

MPN
3RV2032-4VA15