Skip to main content
Siemens 3RV2032-4XA15 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV2032-4XA15 Motor Protection Circuit Breake

MPN3RV2032-4XA15
Active

Siemens SIRIUS circuit breaker for motor protection, 3RV2032-4XA15, Trip Class 10, 50 kA breaking capacity at 400 V, screw terminals, snap-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2032-4XA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2032-4XA15 — Electrical
ParameterValue
Rated operational current (Ie)59 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)26 W
Power loss, per pole (AC, hot)8.7 W
3RV2032-4XA15 — Protection & Tripping
ParameterValue
Overload release setting range49 ... 59 A
Instantaneous short-circuit trip current845 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2032-4XA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h
3RV2032-4XA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 1)
3RV2032-4XA15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2032-4XA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2032-4XA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It's part of the SIRIUS product family, built for motor protection with phase failure detection onboard — no ground fault detection on this variant. Rated operating voltage spans 20 to 690 V. Terminals are screw-type, accepting 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²).

Dimensions are 55 mm wide, 140 mm high, 149 mm deep. That 149 mm depth is the body depth — factor it into enclosure depth clearance, especially if you're running wires behind the rail.

Frequently asked questions

What is the breaking capacity of 3RV2032-4XA15 at 400 V?

The breaking capacity is 50 kA at 400 V rated value.

Does 3RV2032-4XA15 include phase failure detection?

Yes, it has phase failure detection. It does not include ground fault detection.

What mounting method does 3RV2032-4XA15 use?

It mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 60715, in any mounting position.

What wire sizes fit the terminals on 3RV2032-4XA15?

Screw terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire.

Where can I buy 3RV2032-4XA15 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or prices listed here.

MPN
3RV2032-4XA15