Siemens 3RV2041-4FA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2041-4FA10 MPCB, Class 10, 40A, 65kA@400V

MPN3RV2041-4FA10
Active

Siemens SIRIUS 3RV2041-4FA10, motor protection circuit breaker, Class 10, 40 A rated current, screw terminals, 65 kA breaking capacity at 400 V AC.

$413.19Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2041-4FA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2041-4FA10 — Electrical
ParameterValue
Rated operational current (Ie)40 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)23 W
Power loss, per pole (AC, hot)7.7 W
3RV2041-4FA10 — Protection & Tripping
ParameterValue
Overload release setting range28 ... 40 A
Instantaneous short-circuit trip current520 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 000 A
Breaking capacity at 690 V37 kW
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2041-4FA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2041-4FA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
3RV2041-4FA10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2041-4FA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2041-4FA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Class 10 trip — protects the motor winding, not the feeder

Rated at 40 A continuous, the 3RV2041-4FA10 handles motor full-load currents up to that value. The SCCR (short-circuit current rating) of the downstream contactor and overload relay is coordinated with this breaker; the 3RV2041 limits the let-through energy so the contactor survives a fault.

Screw terminals, DIN rail, any position — panel integration

The solid/stranded wire range is 2x (2.5... 16 mm²) for the power circuit, with a larger range of 2x (2.5... 50 mm²) or 1x (10... 70 mm²) available for the load side — sized to handle the full 40 A without derating. The control circuit terminals accept 2x (2.5... 16 mm²) solid or stranded. The dimensions are 70 mm wide, 165 mm high, 176 mm deep.

Active production — quoted to order

Submit an RFQ through the storefront for a current commercial offer.

Frequently asked questions

What is the ampere rating of Siemens 3RV2041-4FA10?

The 3RV2041-4FA10 is rated at 40 A continuous. This is the maximum full-load motor current it is designed to protect. The thermal-magnetic trip mechanism allows adjustment of the overload setting within a range around this value.

Does 3RV2041-4FA10 have screw terminals?

Yes, the main current circuit uses screw-type terminals. The wire range is 2x (2.5... 16 mm²) solid or stranded for the power side, with a larger range available for the load side.

Can 3RV2041-4FA10 be mounted on DIN rail?

Yes. It mounts via screw or snap-on onto a 35 mm DIN rail per DIN EN 60715. The mounting position is any orientation.

MPN
3RV2041-4FA10