Skip to main content
Siemens 3RV2041-4JA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2041-4JA15 SIRIUS Motor Protection Circuit Breake

MPN3RV2041-4JA15
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2041-4JA15, 63 A at 480 V, 30 kA breaking at 400 V, Class 10, phase failure detection, screw terminals, snap-on DIN rail.

$130.81Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2041-4JA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2041-4JA15 — Electrical
ParameterValue
Rated operational current (Ie)63 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)34 W
Power loss, per pole (AC, hot)11.3 W
3RV2041-4JA15 — Protection & Tripping
ParameterValue
Overload release setting range45 ... 63 A
Instantaneous short-circuit trip current819 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2041-4JA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2041-4JA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2041-4JA15 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2041-4JA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2041-4JA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

Rated operating voltage spans 20 to 690 V, covering most low-voltage motor circuits globally. The 176 mm depth fits standard 200 mm deep enclosures — no need for a deeper gland plate. Screw terminals accept solid or stranded conductors: 2×(2.5…16 mm²) for the main circuit and 2×(2.5…50 mm²) or 1×(10…70 mm²) for line/load connections.

Frequently asked questions

What is the 3RV2041-4JA15's breaking capacity at 400 V?

It is rated 30 kA at 400 V, which means it can safely interrupt a fault current up to 30,000 A at that voltage without upstream protection needing to clear.

Will the 3RV2041-4JA15 drop into a panel specified for the 3RV2021-4NA25?

Both are SIRIUS motor protection breakers with the same DIN rail footprint and screw-terminal style, but the 3RV2041-4JA15 is rated for higher current (63 A at 480 V vs the 3RV2021-4NA25's lower rating). Verify the load current and breaking capacity before substitution — the physical fit is the same, but the electrical rating must match the application.

Where can I buy the 3RV2041-4JA15 and get a price?

This part is sourced and quoted to order against an RFQ through our independent distribution. Submit an RFQ request and we will confirm availability and current pricing at quote time.

MPN
3RV2041-4JA15