Siemens SIRIUS motor protection circuit breaker, 3RV2042-4JA10, CLASS 10, screw terminals, 50 kA breaking capacity at 400 V AC, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2042-4JA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2042-4JA10 — Electrical
ParameterValue
Rated operational current (Ie)63 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)34 W
Power loss, per pole (AC, hot)11.3 W
3RV2042-4JA10 — Protection & Tripping
ParameterValue
Overload release setting range45 ... 63 A
Instantaneous short-circuit trip current819 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)15 kA
Breaking capacity at 690 V (AC)7.5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2042-4JA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2042-4JA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
3RV2042-4JA10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2042-4JA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2042-4JA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Dimensions are 70 mm wide, 165 mm high, 176 mm deep, with 150 mm clearance required above and below for arc venting, and 30 mm at the sides. Screw-type terminals on the main circuit accept 2x (2.5 to 16 mm²) solid or stranded, or 1x (10 to 70 mm²) for larger feeds — typical for panel wiring up to 63 A continuous.

Operating conditions and ratings

Rated operational voltage spans 20 to 690 V AC, with a maximum of 15 switching operations per hour at AC-3 duty (motor starting).

Frequently asked questions

Will 3RV2042-4JA10 drop into a panel specified around 3RV2021-4NA25?

Both are SIRIUS motor protection breakers on the same 35 mm DIN rail footprint, but the 3RV2042-4JA10 is a physically larger frame (70 mm wide vs the smaller 3RV2021 frame). Check panel cutout and terminal lug sizes before substituting.

MPN
3RV2042-4JA10