Skip to main content
Siemens 3RV2042-4MA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2042-4MA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2042-4MA10
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2042-4MA10, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 70 x 165 x 176 mm.

$220.98Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2042-4MA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2042-4MA10 — Electrical
ParameterValue
Rated operational current (Ie)100 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)44 W
Power loss, per pole (AC, hot)14.7 W
3RV2042-4MA10 — Protection & Tripping
ParameterValue
Overload release setting range80 ... 100 A
Instantaneous short-circuit trip current1 300 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2042-4MA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2042-4MA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
3RV2042-4MA10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2042-4MA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2042-4MA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2042-4MA10 is a SIRIUS motor protection circuit breaker designed for motor protection, with CLASS 10 trip characteristic meaning it will trip within 10 seconds at 7.2x the thermal setting — fast enough to protect standard induction motors during a locked-rotor event without nuisance tripping on normal starts. Breaking capacity is 100 kA at 400 V AC and 100 kA at 240 V AC, which means this breaker can safely interrupt fault currents up to 100,000 amps at those voltages — sufficient for high-fault panels downstream of large transformers without needing a current-limiting upstream device. Motor horsepower ratings span from 7.5 hp at 110/120 V up to 100 hp at 575/600 V, covering a wide range of industrial motor sizes.

Any mounting position allowed. Dimensions 70 mm wide x 165 mm high x 176 mm deep — the 176 mm depth is the key dimension for enclosure depth clearance; ensure your panel has at least 180 mm usable depth to allow wiring space behind the breaker. Screw-type terminals for the main circuit accept 2x (2.5...16 mm²) solid or stranded, or 1x (10...70 mm²) for larger feeds — flexible enough for both panel internal wiring and incoming supply cables.

Lifecycle stage is current production — this is an active, non-obsolete part in the Siemens SIRIUS catalog, not a phase-out or NRND item. Rated insulation voltage 20...690 V covers standard low-voltage networks up to 690 V phase-to-phase. Maximum switching frequency at AC-3 duty is 15 operations per hour — sufficient for motor starting duty but not for high-speed jogging or frequent cycling applications.

Frequently asked questions

What is the breaking capacity of 3RV2042-4MA10 at 400 V?

100 kA at 400 V AC. Also 100 kA at 240 V AC, 10 kA at 500 V AC, and 6 kA at 690 V AC.

What trip class is 3RV2042-4MA10?

CLASS 10, meaning it will trip within 10 seconds at 7.2x the thermal setting — standard for general-purpose motor protection.

Does 3RV2042-4MA10 have phase failure detection?

Yes, phase failure detection is included. No ground fault detection.

Will 3RV2042-4MA10 drop into a panel specified for 3RV2021-4NA25?

Both are SIRIUS motor protection breakers with the same DIN-rail mounting and similar terminal ranges, but the 3RV2042-4MA10 has higher breaking capacity (100 kA vs lower on the 3RV2021 series) and different dimensions — verify panel depth clearance for the 176 mm depth and check the 150 mm clearance above/below.

How do I get pricing and availability for 3RV2042-4MA10?

Sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm quote with lead time.

MPN
3RV2042-4MA10