Skip to main content
Siemens 3RV2111-0DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2111-0DA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2111-0DA10
Active

Siemens SIRIUS 3RV2111-0DA10 motor protection circuit breaker, Class 10, 100 kA SCCR at 400 V AC, screw and snap-on DIN rail mount.

$50.80Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2111-0DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2111-0DA10 — Electrical
ParameterValue
Rated operational current (Ie)0.32 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2111-0DA10 — Protection & Tripping
ParameterValue
Overload release setting range0.22 ... 0.32 A
Instantaneous short-circuit trip current4.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2111-0DA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2111-0DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2111-0DA10 — Mechanical
ParameterValue
Height97 mm
Width65 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2111-0DA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2111-0DA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

SCCR and breaking capacity

At 240 V AC it's also 100 kA. The SCCR covers the full range from 20 V to 690 V, meaning this breaker can be used on 208 V, 240 V, 400 V, 480 V, and 690 V systems without derating the interrupting rating.

Dimensions: 65 mm wide, 97 mm deep, 97 mm tall.

Terminals and wiring

Screw-type terminals on the main current circuit, accepting 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded copper. Screwdriver shaft diameter 5 to 6 mm.

Frequently asked questions

What is 3RV2111-0DA10's listed depth (97 mm) on this component line?

Depth is 97 mm — that's the dimension from the DIN rail mounting surface to the front of the breaker body, not including any protruding terminals or operator knobs.

MPN
3RV2111-0DA10