Skip to main content
Siemens 3RV2111-0EA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2111-0EA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2111-0EA10
Active

Siemens SIRIUS, motor protection circuit breaker with overload relay function, 3RV2111-0EA10, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV2111-0EA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2111-0EA10 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2111-0EA10 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current5.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2111-0EA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2111-0EA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2111-0EA10 — Mechanical
ParameterValue
Height97 mm
Width65 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2111-0EA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2111-0EA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

The 3RV2111-0EA10 carries a 100 kA breaking capacity at 400 V AC — that's the same high-interrupt rating across the 240 V through 690 V range.

The 3RV2111-0EA10 is listed as current-production status. No official successor or replacement has been issued for this order code.

The 65 mm width occupies three standard 18 mm module spaces on the rail. Any mounting position is permitted, which simplifies layout in crowded enclosures. Clearance distances: 50 mm above and below, 30 mm to the side, zero forward or backward — so it can sit flush against the back panel or enclosure door.

Frequently asked questions

Where can I buy 3RV2111-0EA10 and how do I get a price?

The 3RV2111-0EA10 is sourced and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network.

What is 3RV2111-0EA10's listed depth?

The 3RV2111-0EA10 has a depth of 97 mm, a width of 65 mm, and a height of 97 mm.

What compliance documentation does this brand provide for 3RV2111-0EA10?

As a Siemens SIRIUS product, the 3RV2111-0EA10 is designed to meet applicable IEC and UL standards for motor protection circuit breakers. Specific compliance declarations (RoHS, REACH, UL, IEC) are available from the manufacturer's documentation portal for this order code.

MPN
3RV2111-0EA10