Siemens 3RV2111-0FA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2111-0FA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2111-0FA10
Active

Siemens SIRIUS 3RV2111-0FA10, motor protection circuit breaker with overload relay function, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw-type terminals, DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2111-0FA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2111-0FA10 — Electrical
ParameterValue
Rated operational current (Ie)0.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2111-0FA10 — Protection & Tripping
ParameterValue
Overload release setting range0.35 ... 0.5 A
Instantaneous short-circuit trip current6.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2111-0FA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2111-0FA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2111-0FA10 — Mechanical
ParameterValue
Height97 mm
Width65 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2111-0FA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2111-0FA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

Motor protection circuit breaker, SIRIUS series

Phase failure detection is included; ground fault detection is not built in.

At 230 V rated value it handles 0.1 kW motor loads, so it is sized for smaller motors in conveyor, pump, or fan duty. Class 10 trip ensures the breaker disconnects before the motor winding overheats during a stall — the standard for standard-duty induction motors. The 15 operations per hour maximum at AC-3 duty governs repetitive starting; a furnace fan cycling more often needs a higher-rated device. The operating temperature range of -20 to +60 °C with temperature compensation allows deployment in unconditioned enclosures near furnaces or ovens, as long as the ambient stays within that span. Storage range extends to -50 to +80 °C.

Any mounting position is permitted. Clearance requirements: 50 mm upwards and downwards, 0 mm forwards and backwards, 30 mm at the side — tight enough for dense panels. Dimensions are 97 mm deep, 65 mm wide, and 97 mm high. The M3 screw terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded conductors.

Frequently asked questions

Where can I buy 3RV2111-0FA10?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV2111-0FA10?

The rated breaking capacity is 100 kA at 400 V AC, and also 100 kA at 240 V, 500 V, and 690 V AC.

What does Class 10 trip mean for this motor protection breaker?

Class 10 means the breaker trips within 10 seconds at a locked-rotor condition, protecting standard induction motors from overheating during a stall.

MPN
3RV2111-0FA10