Skip to main content
Siemens 3RV2111-1JA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2111-1JA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2111-1JA10
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2111-1JA10, Trip Class 10, 100 kA breaking capacity at 400 V, screw and snap-on 35 mm DIN rail mounting.

$59.69Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2111-1JA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2111-1JA10 — Electrical
ParameterValue
Rated operational current (Ie)10 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2111-1JA10 — Protection & Tripping
ParameterValue
Overload release setting range7 ... 10 A
Instantaneous short-circuit trip current130 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2111-1JA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2111-1JA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2111-1JA10 — Mechanical
ParameterValue
Height97 mm
Width65 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2111-1JA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2111-1JA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

This saves a panel builder a component and the wiring between a separate breaker and overload relay. Breaking capacity sits at 100 kA at 400 V and 240 V, dropping to 42 kA at 500 V and 4 kA at 690 V.

Any mounting position is allowed, which simplifies layout in crowded enclosures. Dimensions are 97 mm deep, 65 mm wide, and 97 mm high. Clearance requirements: 50 mm above and below, 30 mm to the side, zero front and back. Main circuit terminals accept 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded wire, terminated with M3 screws. This covers standard motor connection cables up to 2.5 mm².

MPN
3RV2111-1JA10