Siemens 3RV2131-4SA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2131-4SA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2131-4SA10
Active

Siemens SIRIUS 3RV2131-4SA10 motor protection circuit breaker, CLASS 10, 100 kA at 240 V, 30 kA at 400 V, screw/snap-on DIN rail, 149 x 75 x 140 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV2131-4SA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2131-4SA10 — Electrical
ParameterValue
Rated operational current (Ie)14 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)12.5 W
Power loss, per pole (AC, hot)4.2 W
3RV2131-4SA10 — Protection & Tripping
ParameterValue
Overload release setting range9.5 ... 14 A
Instantaneous short-circuit trip current208 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2131-4SA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2131-4SA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)
3RV2131-4SA10 — Mechanical
ParameterValue
Height140 mm
Width75 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2131-4SA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2131-4SA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

Rated insulation voltage spans 20 to 690 V. Breaking capacity is voltage-dependent: 100 kA at 240 V, 30 kA at 400 V, 6 kA at 500 V, and 2 kA at 690 V. Phase failure detection is included; ground fault detection is not. The main circuit connects via screw-type terminals accepting up to 2× 25 mm² or 1× 35 mm² solid or stranded copper, with M6 contact screws.

The breaker occupies 75 mm width, 140 mm height, and 149 mm depth. Mounting position is any orientation. Required clearances: 50 mm upwards, 50 mm downwards, 10 mm to the side, 0 mm forwards and backwards — so it can be stacked tightly against the back panel or adjacent devices without extra air gap.

Environmental and Operating Limits

Maximum switching rate under AC-3 duty is 15 operations per hour.

The 3RV2131-4SA10 carries a current lifecycle stage.

Frequently asked questions

What is 3RV2131-4SA10's listed note (1) on this component line?

The evidence lists a Note value of 1, which typically indicates a general remark or condition in the manufacturer's documentation.

Will 3RV2131-4SA10 drop into a panel that was specified around 3RV1011-1HA10 without rewiring?

The 3RV2131-4SA10 mounts on the same 35 mm DIN rail standard and uses screw terminals, but the 3RV1011-1HA10 is a different frame size and rating — verify the terminal layout and clearance dimensions before direct swap.

MPN
3RV2131-4SA10