Skip to main content
Siemens 3RV2131-4TA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2131-4TA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2131-4TA10
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2131-4TA10, Class 10 trip, 30 kA SCCR at 400 V, screw-type terminals, snap-on 35 mm DIN rail.

$95.25Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2131-4TA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2131-4TA10 — Electrical
ParameterValue
Rated operational current (Ie)17 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV2131-4TA10 — Protection & Tripping
ParameterValue
Overload release setting range12 ... 17 A
Instantaneous short-circuit trip current260 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2131-4TA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2131-4TA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
3RV2131-4TA10 — Mechanical
ParameterValue
Height140 mm
Width75 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2131-4TA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2131-4TA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

The Siemens 3RV2131-4TA10 is a SIRIUS motor-protection circuit breaker with integrated overload relay function, designed for screw-and-snap-on mounting onto 35 mm DIN rail per DIN EN 60715. It handles motor starting duty at up to 15 switching cycles per hour in AC-3 service, with a Trip Class 10 characteristic that clears overloads fast enough to protect standard induction motors from heat damage during stalled-rotor conditions.

This breaker carries a short-circuit breaking capacity of 100 kA at 240 V, 30 kA at 400 V, 6 kA at 500 V, and 2 kA at 690 V. At 400 V — the most common industrial distribution voltage — a 30 kA SCCR means it can safely interrupt a fault up to that level without welding contacts or cascading failure upstream, so it coordinates with most 400 V switchgear rated for 36 kA or higher.

Deployment context — where this part lives in the panel

The screw-type main terminals accept 2x 1…25 mm² or 1x 1…35 mm² solid or stranded copper — sized for motor feeders up to around 7.5 kW at 400 V. Operating temperature range of -20 to +60 °C means it survives inside a non-air-conditioned enclosure near a kiln or compressor; storage range of -50 to +80 °C covers transport and warehouse extremes.

Frequently asked questions

What is the interrupting capacity of 3RV2131-4TA10 at 400 V?

At 400 V the short-circuit breaking capacity is 30 kA, which coordinates with typical 400 V switchgear rated for 36 kA or higher.

What trip class is 3RV2131-4TA10?

Trip Class 10, meaning it clears overloads within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors from heat damage during a stalled rotor.

Where can I buy 3RV2131-4TA10?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV2131-4TA10