Siemens 3RV2142-4KA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2142-4KA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2142-4KA10
Active

Siemens SIRIUS, motor protection circuit breaker with overload relay function, 3RV2142-4KA10, CLASS 10 trip, 50 kA at 400 V, 75 A at 480 V, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2142-4KA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2142-4KA10 — Electrical
ParameterValue
Rated operational current (Ie)75 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)38 W
Power loss, per pole (AC, hot)12.7 W
3RV2142-4KA10 — Protection & Tripping
ParameterValue
Overload release setting range57 ... 75 A
Instantaneous short-circuit trip current975 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2142-4KA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2142-4KA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2142-4KA10 — Mechanical
ParameterValue
Height165 mm
Width90 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2142-4KA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2142-4KA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection with overload relay function

Product details

At 480 V it carries 75 A continuous, so it handles motor FLA up to that figure in a 480 V system.

The 90 mm width and 176 mm depth mean it occupies three standard 18 mm module slots on the rail — a common footprint for this class of SIRIUS breaker. That side clearance is tighter than some competing breakers; if you're packing multiple units side-by-side, keep that 30 mm minimum for arc venting and terminal access. Screw-type terminals on the main circuit accept solid or stranded: 2x (2.5 to 16 mm²) for the smaller wire, and 2x (2.5 to 50 mm²) or 1x (10 to 70 mm²) for the larger. That covers most motor feeder cables up to about 70 mm² — common for 75 A circuits.

Frequently asked questions

What is the interrupting rating of the 3RV2142-4KA10 at 400 V?

The 3RV2142-4KA10 has a 50 kA interrupting rating at 400 V, which determines the maximum fault current it can safely clear at that voltage.

What trip class is the 3RV2142-4KA10?

The trip class is CLASS 10, meaning it will trip within 10 seconds at 600% of the set current, suitable for standard motor starting.

Where can I buy the 3RV2142-4KA10 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV2142-4KA10