Siemens 3RV2311-0BC20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2311-0BC20 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2311-0BC20
Active

Siemens SIRIUS circuit breaker for starter combinations, size S00, 3RV2311-0BC20, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, screw and snap-on 35 mm DIN rail mounting.

$31.75Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2311-0BC20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2311-0BC20 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2311-0BC20 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current2.6 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2311-0BC20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2311-0BC20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
3RV2311-0BC20 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2311-0BC20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2311-0BC20 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

SIRIUS 3RV2311-0BC20 — Motor Starter Protector, Size S00

Its headline rating is a 100 kA breaking capacity at 400 V AC, which means it can safely interrupt a fault current up to 100,000 amps without welding contacts or cascading failure upstream in the panel. That level of SCCR (short-circuit current rating) covers most industrial distribution systems straight off the transformer. Rated for AC-3 duty up to 690 V, this protector handles the switching of motor loads — starting and stopping under load — with a typical mechanical life of 100,000 operations on the main contacts. The 100 kA rating holds at 240 V, 400 V, 500 V, and 690 V AC, so you get consistent fault-clearing performance across common supply voltages without derating the interrupting capacity.

The S00 footprint is 45 mm wide, 106 mm tall, 97 mm deep — a compact single-module width that leaves room for adjacent contactors or auxiliaries in a motor control center row. Spring-loaded terminals on the main circuit accept 2 x (0.5 to 4 mm²) solid or stranded wire; no lug torqueing needed, just strip and push. That lets you pack units tightly in a shallow enclosure as long as you respect the vertical ventilation gap.

Frequently asked questions

What is the breaking capacity of 3RV2311-0BC20?

100 kA at 240 V, 400 V, 500 V, and 690 V AC. That covers the common industrial supply voltages without derating the interrupting rating.

Where can I buy 3RV2311-0BC20 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3RV2311-0BC20 drop into a panel specified for 3RV2011-0BA20?

Both are S00-frame Siemens circuit breakers on the same 45 mm DIN-rail footprint, so the mechanical fit and terminal layout are the same. Check the trip curve and current rating on your specific 3RV2011 variant — the 3RV2311-0BC20 is designed for starter combinations and may have different overload settings.

MPN