3RV2311-0EC20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2311-0EC20 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2311-0EC20 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current5.2 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2311-0EC20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2311-0EC20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
3RV2311-0EC20 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2311-0EC20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2311-0EC20 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

Any mounting position allowed, so it fits tight enclosures or vertical bus drops. Dimensions 97 mm deep, 45 mm wide, 106 mm tall — the 45 mm width (3 module spaces) is standard for size S00 breakers, making panel layout and fill factor predictable. The screwdriver shaft diameter is 3 mm, tip size 3.0 x 0.5 mm — use a slim-profile driver to avoid damaging adjacent terminals in a dense row.

Electrical ratings and duty

Rated operational voltage spans 20 to 690 V. At 230 V it handles 0.1 kW motor load (AC-3 duty), and at 480 V and 600 V the rated current drops to 0.4 A — so for higher-voltage motor circuits, size the breaker to the motor FLA, not the voltage alone. Breaking capacity holds at 100 kA across 240 V, 400 V, 500 V, and 690 V AC, giving solid SCCR headroom for most industrial panel designs. Rated for 15 switching operations per hour at AC-3 and AC-3e maximum — sufficient for typical motor starting cycles in conveyor or pump duty. Mechanical endurance of the main contacts is 100,000 operations typical, so it outlasts many contactors in the same branch.

Frequently asked questions

What is the breaking capacity of 3RV2311-0EC20 at 400 V?

100 kA at 400 V AC, which means it safely interrupts fault currents up to that level without cascading upstream.

Will 3RV2311-0EC20 drop into a panel specified around 3RV2011-0BA20 without rewiring?

Both are size S00 breakers on 35 mm DIN rail, but the 3RV2311-0EC20 uses spring-loaded terminals while the 3RV2011-0BA20 may use screw terminals — verify the wiring interface before swapping.

What is the width of 3RV2311-0EC20?

45 mm, which is standard for size S00 breakers and fits three module spaces on a DIN rail.

Where can I buy 3RV2311-0EC20?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
3RV2311-0EC20