Siemens 3RV2311-0JC20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2311-0JC20 SIRIUS Circuit Breaker, S00, 100 kA at

MPN3RV2311-0JC20
Active

Siemens SIRIUS circuit breaker, 3RV2311-0JC20, for starter combinations, size S00, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2311-0JC20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2311-0JC20 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2311-0JC20 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current13 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2311-0JC20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2311-0JC20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)

Mechanical

3RV2311-0JC20 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2311-0JC20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2311-0JC20 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

The Siemens 3RV2311-0JC20 is a SIRIUS circuit breaker designed specifically for starter combinations — meaning it integrates directly into motor starter assemblies, providing short-circuit and overload protection in a single compact unit. Its size S00 frame (45 mm wide, 97 mm deep, 106 mm tall) fits the standard 35 mm DIN rail per DIN EN 60715, with screw and snap-on mounting that lets you clip it into a panel without tools. The 100 kA breaking capacity at 400 V AC (and equally at 240 V, 500 V, 690 V) means it can safely interrupt high fault currents common in industrial distribution, protecting downstream contactors and motor loads without cascading upstream. For a 230 V motor circuit, it supports up to 0.2 kW motor power, sized for small drives like pumps or conveyors.

Compared to the earlier SIRIUS 3RV2011-0BA20 (also size S00, 100 kA at 400 V), the 3RV2311-0JC20 shares the same frame footprint and breaking capacity, but the 3RV2311 is designated for starter combinations while the 3RV2011 is a general-purpose motor-protective breaker. The 3RV2311-0JC20 uses spring-loaded terminals for the main circuit, whereas the 3RV2011-0BA20 typically uses screw terminals — so a panel wired for screw terminals may require terminal adapter or re-termination if swapping directly. Both mount on 35 mm DIN rail, so the mechanical fit is identical.

Mounting position is any orientation, which simplifies panel layout. The spring-loaded terminals accept 2x (0.5 to 4 mm²) solid or stranded wire — no ferrules needed, but a 3 mm diameter screwdriver shaft is specified for the terminal screws. Clearance requirements: 50 mm upwards and downwards, 30 mm to the sides, 0 mm forwards and backwards — so it sits flush against the mounting plate. Ambient operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C.

Frequently asked questions

What is the breaking capacity of 3RV2311-0JC20 at 400 V?

It is rated 100 kA at 400 V AC, and the same 100 kA at 240 V, 500 V, and 690 V AC.

Will 3RV2311-0JC20 drop into a panel specified for 3RV2011-0BA20?

Mechanically yes — both are size S00 and mount on 35 mm DIN rail. However, the 3RV2311 uses spring-loaded terminals, while the 3RV2011 typically uses screw terminals, so the wiring termination method differs.

Where can I buy 3RV2311-0JC20 and how is it quoted?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.