Skip to main content
Siemens 3RV2321-1BC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2321-1BC10 SIRIUS Circuit Breaker, Size S0, 100 k

MPN3RV2321-1BC10
Active

Siemens SIRIUS circuit breaker for starter combinations, size S0, 45 mm width, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2321-1BC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2321-1BC10 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2321-1BC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current26 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2321-1BC10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2321-1BC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
3RV2321-1BC10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2321-1BC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2321-1BC10 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

The S0 frame is 45 mm wide and 97 mm deep — that 45 mm width is the critical panel-space dimension; it occupies one standard 45 mm slot on the rail. The main-circuit terminals accept screw-type connections, M4 thread, with a wire range of 2x 1–2.5 mm² or 2x 2.5–10 mm² solid or stranded.

Lifecycle status is current — no phase-out, no NRND flag. That means it's a standard catalog item, not a discontinued part you'd need to broker. For a tail-spend buyer, this is the kind of line you want on a preferred-supplier punch-out: consistent availability, no maverick sourcing. The 3RV2321-1BC10 is the exact order code for the BOM; no substitute needed.

Frequently asked questions

Will 3RV2321-1BC10 drop into a panel that was specified around 3RV2011-0AA10 without rewiring?

No — the 3RV2321-1BC10 is a Size S0 breaker for starter combinations, while the 3RV2011-0AA10 is a different frame size and function. Panel fit, terminal spacing, and coordination with the contactor differ; verify the mechanical and electrical layout before substituting.

MPN
3RV2321-1BC10