Skip to main content
Siemens 3RV2321-1FC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2321-1FC10 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2321-1FC10
Active

Siemens SIRIUS circuit breaker for starter combinations, 3RV2321-1FC10, 45 mm width, 97 mm depth, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2321-1FC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2321-1FC10 — Electrical
ParameterValue
Rated operational current (Ie)5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2321-1FC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current65 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2321-1FC10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2321-1FC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
Conductor range, AWG (main contacts)2x (16 ... 12), 2x (14 ... 8)
3RV2321-1FC10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2321-1FC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2321-1FC10 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

SIRIUS 3RV2321-1FC10 — Motor Circuit Breaker for Starter Combinations

Breaking Capacity and Motor Ratings

Breaking capacity holds at 100 kA across the common industrial voltages: 240 V, 400 V, and 500 V AC. Motor horsepower ratings span 0.17 hp at 110/120 V up to 3 hp at 460/480 V and 575/600 V, covering fractional to medium motor loads common in conveyor, pump, and fan applications.

The 45 mm width occupies two standard 22.5 mm module spaces. Clearance requirements: 50 mm upwards and downwards, 30 mm at the side, zero forwards or backwards — so it can be placed flush against a backplate or enclosure wall. Main contact terminals accept M4 screws and 2x (1 to 2.5 mm²) or 2x (2.5 to 10 mm²) solid or stranded wire.

Environmental and Operating Conditions

Rated insulation voltage spans 20 to 690 V, covering low-voltage control circuits through 690 V motor feeds. The part does not include ground fault or phase failure detection — those functions must be provided externally if required by the application.

Frequently asked questions

What is the breaking capacity of 3RV2321-1FC10 at 400 V?

100 kA at 400 V AC, which is the same rating at 240 V and 500 V AC. At 690 V AC the capacity is 4 kA.

What motor sizes does 3RV2321-1FC10 protect?

It covers motors from 0.17 hp at 110/120 V up to 3 hp at 460/480 V and 575/600 V. At 230 V it is rated 0.5 hp; at 200/208 V, 1 hp.

Does 3RV2321-1FC10 include ground fault or phase failure detection?

No. Ground fault detection and phase failure detection are not built in. These functions must be provided by an external device if required.

Where can I buy 3RV2321-1FC10 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV2321-1FC10