Siemens 3RV2321-4PC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2321-4PC10 SIRIUS Circuit Breaker, 10 kA at 400 V

MPN3RV2321-4PC10
Active

Siemens SIRIUS circuit breaker for starter combinations, 3RV2321-4PC10, 45 mm wide, 10 kA interrupting capacity at 400 V AC, screw-type terminals, DIN-rail snap-on mounting.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2321-4PC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0

Electrical

3RV2321-4PC10 — Electrical
ParameterValue
Rated operational current (Ie)36 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)16.25 W
Power loss, per pole (AC, hot)5.4 W

Protection & Tripping

3RV2321-4PC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current468 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)20 kA
Breaking capacity at 500 V (AC)6 kA
Breaking capacity at 690 V (AC)3 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2321-4PC10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2321-4PC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
Conductor range, AWG (main contacts)2x (16 ... 12), 2x (14 ... 8)

Mechanical

3RV2321-4PC10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2321-4PC10 — Environmental
ParameterValue
Operating temperature-20 ... +40 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2321-4PC10 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

The Siemens 3RV2321-4PC10 is a SIRIUS circuit breaker designed for starter combinations — meaning it integrates directly into a motor starter assembly, providing short-circuit and overload protection in one compact package. This is not a general-purpose branch breaker; it is sized and coordinated for use with a contactor and overload relay in a motor control center or standalone starter. Rated 10 kA at 400 V AC, this breaker safely interrupts fault currents up to that level without cascading upstream — essential for meeting the SCCR (short-circuit current rating) requirements of the panel label per UL 508A and IEC 60947-2. At 690 V the interrupting rating drops to 2 kA, so verify the available fault current at the point of installation. Mounting is screw and snap-on onto a 35 mm DIN rail per DIN EN 60715, with a 45 mm width that occupies a single modular space. The 97 mm depth and height keep the profile tight for shallow enclosures. Any mounting position is permitted, and the clearance requirements are: 50 mm above and below, 30 mm to the sides, zero forward and backward — so the breaker can sit flush against the back panel without derating. Terminals accept solid or stranded conductors: 2x 1–2.5 mm² or 2x 2.5–10 mm², with M4 screw-type connections on the main contacts. No ground-fault or phase-failure detection onboard — this is a straightforward thermal-magnetic or electronic trip unit for motor overload and short-circuit protection only.

Frequently asked questions

What is 3RV2321-4PC10's listed depth and width?

Depth is 97 mm, width is 45 mm, height is 97 mm — a standard 45 mm modular footprint for DIN-rail mounting.