Siemens 3RV2341-4KC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2341-4KC10 SIRIUS Circuit Breaker, 30 kA at 400 V

MPN3RV2341-4KC10
Active

Siemens SIRIUS, circuit breaker for starter combinations, 3RV2341-4KC10, 30 kA at 400 V, 65 kA at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2341-4KC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2341-4KC10 — Electrical
ParameterValue
Rated operational current (Ie)75 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)38 W
Power loss, per pole (AC, hot)12.7 W
3RV2341-4KC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current975 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2341-4KC10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2341-4KC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
3RV2341-4KC10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2341-4KC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2341-4KC10 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

The Siemens SIRIUS 3RV2341-4KC10 is a circuit breaker designed for starter combinations — the kind you drop into a motor control center to protect the feeder and the contactor downstream. The interrupting ratings tell the real story here: 30 kA at 400 V and 65 kA at 400 V AC. At 240 V AC it's rated 100 kA, so it also covers secondary-side faults in step-down transformers. Terminal capacity is generous: screw-type terminals accept 2x (2.5 to 16 mm²) solid or stranded on the control side, and 1x (10 to 70 mm²) or 2x (2.5 to 50 mm²) on the main circuit. That covers most motor feeder cables up to around 75 A at 600 V (the rated current at 600 V is 75 A).

Dimensions and spacing

The breaker occupies 70 mm width, 165 mm height, and 176 mm depth — a compact footprint for a device that can interrupt 65 kA. That means you can butt it against the backplane or a busbar without extra air gap.

Frequently asked questions

What is the interrupting rating of 3RV2341-4KC10 at 400 V?

At 400 V the breaker is rated 30 kA; at 400 V AC it is rated 65 kA. The higher AC figure applies when the supply is AC, not DC.

What mounting does 3RV2341-4KC10 require?

It mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, in any orientation. Clearance needed: 150 mm above and below, 30 mm to the sides.

Where can I buy 3RV2341-4KC10?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV2341-4KC10