Siemens 3RV2342-4RC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2342-4RC10 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2342-4RC10
Active

Siemens SIRIUS circuit breaker, 3RV2342-4RC10, for starter combinations, screw-type terminals, 100 kA breaking capacity at 400 V AC, 176 mm depth, 70 mm width, 165 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2342-4RC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2342-4RC10 — Electrical
ParameterValue
Rated operational current (Ie)84 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)34 W
Power loss, per pole (AC, hot)11.3 W
3RV2342-4RC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current1 170 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2342-4RC10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2342-4RC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
3RV2342-4RC10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2342-4RC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2342-4RC10 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

SIRIUS circuit breaker for starter combinations

The Siemens 3RV2342-4RC10 is a SIRIUS circuit breaker specifically designed for starter combinations, meaning it integrates motor protection and disconnection in a single device sized for the motor branch circuit rather than a general distribution feeder. This is the part to specify when the BOM calls for coordinated motor starter protection — not a standalone MCCB for a panel main.

At 400 V AC, this breaker delivers 100 kA breaking capacity — the same high-interrupt rating it carries at 240 V AC. Motor horsepower ratings span 7.5 hp at 110/120 V up to 75 hp at 575/600 V, covering a wide range of North American motor frames. The 84 A continuous rating at 480 V and 600 V matches common motor full-load current for 60 hp and 75 hp NEMA designs respectively.

Clearance requirements: 150 mm above and below for arc venting and cable bending, 30 mm at the sides, and zero clearance forward or backward. No extra side space needed between adjacent devices. Screw-type terminals on the main circuit accept 2x (2.5 to 16 mm²) solid or stranded conductors, with a single-wire option up to 70 mm².

Environmental and voltage range

The rated voltage range is 20 to 690 V, covering low-voltage control circuits through 690 V industrial mains.

Frequently asked questions

What is 3RV2342-4RC10's depth?

The depth is 176 mm, with a width of 70 mm and height of 165 mm. Clearance required: 150 mm above and below, 30 mm at the sides, zero forward or backward.

What wire sizes does the 3RV2342-4RC10 terminal accept?

Screw-type terminals accept 2x (2.5 to 16 mm²) solid or stranded, or a single conductor up to 70 mm².

Will 3RV2342-4RC10 drop into a panel specified around 3RV2021-4NA25 without rewiring?

The 3RV2342-4RC10 is a different frame size (70 mm wide, 176 mm deep) compared to the 3RV2021 series. While both mount on 35 mm DIN rail, the 3RV2342 is physically larger and has higher interrupting ratings — verify panel cutout dimensions and bus bar spacing before substituting.

MPN
3RV2342-4RC10