Skip to main content
Siemens 3RV2342-4YC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2342-4YC10 SIRIUS Circuit Breaker, 50 kA at 400 V

MPN3RV2342-4YC10
Active

Siemens SIRIUS, circuit breaker for starter combinations, 3RV2342-4YC10, 50 kA at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2342-4YC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS3
3RV2342-4YC10 — Electrical
ParameterValue
Rated operational current (Ie)93 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 31 000 V
Rated impulse withstand voltage (Uimp)8 kV
Number of poles3
Power loss (AC, hot)39 W
Power loss, per pole (AC, hot)13 W
3RV2342-4YC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current1 300 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2342-4YC10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)25 000
Endurance, auxiliary contacts (typ.)25 000
Switching frequency, AC-3 (max.)15 1/h
3RV2342-4YC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Conductor cross-section, finely stranded with ferrule2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
3RV2342-4YC10 — Mechanical
ParameterValue
Height165 mm
Width70 mm
Depth176 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2342-4YC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2342-4YC10 — Specifications
ParameterValue
Design Of The ProductFor starter combinations

Product details

Screw-type terminals on the main circuit accept solid or stranded conductors: 2x (2.5 … 50 mm²) or 1x (10 … 70 mm²) for the power path, and 2x (2.5 … 16 mm²) for the control/auxiliary circuit. The 176 mm depth and 70 mm width fit standard 8-module DIN-rail spacing — no overhang into adjacent device slots. Clearance requirements: 150 mm upwards and downwards, 30 mm at the sides, zero forwards or backwards.

Frequently asked questions

Where can I buy 3RV2342-4YC10 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is 3RV2342-4YC10's interrupting rating at 400 V?

50 kA at 400 V AC (and 100 kA at 240 V AC). At 690 V AC the rating is 6 kA.

What clearance is needed around 3RV2342-4YC10?

150 mm upwards and downwards, 30 mm at the sides, zero forwards or backwards.

MPN
3RV2342-4YC10