Siemens 3RV2411-0BA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-0BA15 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV2411-0BA15
Active

Siemens SIRIUS circuit breaker, 3RV2411-0BA15, for transformer protection, 100 kA breaking capacity at 400 V AC, Trip Class 10, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-0BA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-0BA15 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2411-0BA15 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Instantaneous short-circuit trip current4.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-0BA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-0BA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2411-0BA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-0BA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-0BA15 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

The Siemens SIRIUS 3RV2411-0BA15 is a circuit breaker specifically designed for transformer protection. The Trip Class 10 characteristic ensures fast disconnection during overloads, protecting the transformer winding from thermal stress.

The 100 kA breaking capacity at 400 V AC (and also at 240 V, 500 V, and 690 V AC) means this breaker can safely interrupt very high fault currents without failing — critical for transformer primary-side protection where inrush and fault currents can be severe. The rated operational voltage spans 20 to 690 V, covering most low-voltage industrial supplies. Ground fault detection is not included, so if that's required, an external GFCI module is needed. Auxiliary contact ratings are provided for control circuit integration: 1 A at 24 V, 0.5 A at 120/125/230 V, and 0.15 A at 60 V. These are the switching capacities for the built-in auxiliary contacts, not the main power path.

Any mounting position is permitted. Clearance requirements: 50 mm upwards and downwards, 30 mm at the side, 0 mm forwards and backwards. Screw-type terminals on the main current circuit accept 2x (0.5...1.5 mm²) or 2x (0.75...2.5 mm²) solid or stranded wire. Main contact terminal screws are M3. The design is for transformer protection, so it's sized for the inrush and sustained load profile of a transformer, not a motor.

Environmental and Operating Conditions

The maximum switching frequency at AC-3 and AC-3e duty is 15 operations per hour.

Frequently asked questions

What is the breaking capacity of 3RV2411-0BA15?

The breaking capacity is 100 kA at 400 V AC, and also at 240 V, 500 V, and 690 V AC. This is a high-fault-current rating suitable for transformer primary protection.

Will 3RV2411-0BA15 drop into a panel specified around 3RV2011-0AA10?

Both are SIRIUS circuit breakers with the same DIN rail footprint and similar terminal arrangements, but the 3RV2411-0BA15 is specifically designed for transformer protection, while the 3RV2011-0AA10 is a general-purpose motor-protective breaker. Check the auxiliary contact configuration and trip curve before swapping — the physical mounting is compatible, but the protection function differs.

Where can I buy 3RV2411-0BA15 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm lead time.