Siemens 3RV2411-0CA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-0CA10 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2411-0CA10
Active

Siemens SIRIUS circuit breaker, 3RV2411-0CA10, Size S00, for transformer protection, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-0CA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-0CA10 — Electrical
ParameterValue
Rated operational current (Ie)0.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2411-0CA10 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Instantaneous short-circuit trip current5.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-0CA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-0CA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-0CA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-0CA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-0CA10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

Transformer-protection breaker, Size S00

Any mounting position works. That 45 mm width is the critical panel-density number: it occupies one standard 45 mm module slot, so a 12-way panel row holds 12 of these breakers.

Accepts 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm². Screwdriver shaft diameter 5 to 6 mm, Pozidriv size 2 tip. Main contact screws are M3. No ground-fault detection built in; phase-failure detection is included.

Environmental and ratings

Rated voltage 20 to 690 V. Maximum switching frequency in AC-3 duty is 15 operations per hour. The 100 kA breaking capacity repeats across 240 V, 400 V, 500 V, and 690 V AC — so it holds its interrupting rating across the full low-voltage range, not just at one voltage point.

Frequently asked questions

Where can I buy the 3RV2411-0CA10?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the closest functional alternative to the 3RV2411-0CA10?

The 3RV2011-0AA10 is the closest functional peer within the SIRIUS range — same Size S00 frame and Trip Class 10, but it is a general motor-protection breaker, not transformer-protection-specific. The 3RV2411-0CA10's 100 kA breaking capacity at 400 V is higher than the 3RV2011-0AA10's typical 55 kA at 400 V, so the 3RV2411-0CA10 is the correct choice where higher interrupting capacity is specified for transformer duty.

Does the 3RV2411-0CA10 drop into a panel built for the 3RV2011-0AA10?

Yes — both are Size S00, same 45 mm width and DIN-rail snap-on mounting per DIN EN 60715. Terminal type and wire range are identical (screw-type, 0.75–4 mm²). No rewiring needed for the same footprint.

What compliance documentation is available for the 3RV2411-0CA10?

The SIRIUS series carries UL, CSA, CE, and IEC certifications standard for the product line. RoHS and REACH declarations are available from Siemens documentation. Specific certificate numbers for this order code are confirmed at order time.