Skip to main content
Siemens 3RV2411-0CA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-0CA15 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2411-0CA15
Active

Siemens SIRIUS 3RV2411-0CA15 circuit breaker for transformer protection, Trip Class 10, 100 kA at 400 V, 45 mm width, screw and snap-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2411-0CA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-0CA15 — Electrical
ParameterValue
Rated operational current (Ie)0.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2411-0CA15 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Instantaneous short-circuit trip current5.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-0CA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-0CA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-0CA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2411-0CA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-0CA15 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

The Siemens 3RV2411-0CA15 is a SIRIUS-branded circuit breaker specifically designed for transformer protection — not a general-purpose motor protector or feeder breaker. That distinction matters: it's built to handle the inrush and fault characteristics of a transformer primary, with Trip Class 10 thermal overload response.

Screw-type terminals on the main circuit, accepting 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded copper. M3 terminal screws — standard screwdriver, no special tooling. The 97 mm depth and 97 mm height are compact enough for shallow enclosures. If you're retrofitting into a panel that had a 3RV2011-0AA10, the footprint and terminal layout are similar enough that you won't be redrilling the rail or re-terminating the whole bucket — just check the clearance above and below for the 50 mm requirement.

Frequently asked questions

What is 3RV2411-0CA15's listed depth (97 mm) on this component line?

The listed depth is 97 mm. Height is also 97 mm, width is 45 mm — fits a standard modular DIN-rail slot.

What compliance documentation does this brand provide for 3RV2411-0CA15?

Standard SIRIUS circuit breakers carry CE, UL, CSA, and IEC certifications. RoHS and REACH declarations are available on request. Specific country variants (UKCA, EAC) can be confirmed at order time.

MPN
3RV2411-0CA15