Skip to main content
Siemens 3RV2411-0EA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-0EA10 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV2411-0EA10
Active

Siemens SIRIUS S00 circuit breaker, 3RV2411-0EA10, for transformer protection, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm wide, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-0EA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-0EA10 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2411-0EA10 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-0EA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-0EA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-0EA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-0EA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-0EA10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

That means its trip curve and ratings are tuned for the inrush and overload profile of a transformer primary, not a motor — the Trip Class 10 characteristic gives you a fast enough response to protect the winding without nuisance tripping on magnetizing inrush.

The S00 frame size gives you a 45 mm wide body with 97 mm depth and height — about two standard MCB modules wide, so it fits neatly into a motor control center or distribution board. That zero forward clearance means it can sit flush against a panel door or busbar cover without extra standoffs. Screw-type terminals on the main circuit accept 2x 0.75–2.5 mm² or 2x 4 mm² solid/stranded; M3 screws on the main contacts. Use a Pozidriv size 2 tip with a 5–6 mm diameter shaft. Mounting position is any — handy for tight enclosures where you have to lay it on its side.

Frequently asked questions

Will 3RV2411-0EA10 drop into a panel designed for 3RV2011-0AA10?

Both are S00 frame size with the same 45 mm width and 35 mm DIN rail mount, so the physical footprint is the same. The terminal arrangement and screw-type connections are identical. The difference is the trip characteristic: the 3RV2411 is tuned for transformer protection, while the 3RV2011 series covers motor protection. Check your load type before swapping.

MPN
3RV2411-0EA10