Siemens 3RV2411-0EA20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-0EA20 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV2411-0EA20
Active

Siemens SIRIUS, circuit breaker for transformer protection, 3RV2411-0EA20, frame size S00, Class 10 trip, 100 kA interrupting capacity at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2411-0EA20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-0EA20 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2411-0EA20 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-0EA20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-0EA20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2411-0EA20 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2411-0EA20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-0EA20 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

Dimensions are 45 mm wide, 97 mm deep, 106 mm tall — the 45 mm width matches the standard S00 footprint, occupying one 45 mm module on the DIN rail. Screwdriver shaft diameter 3 mm, tip size 3.0 x 0.5 mm for the terminal actuation.

Temperature compensation is active across the full operating range.

No ground fault detection on this variant — that function is handled separately upstream or by a dedicated RCD. The breaker is for transformer primary protection only.

Frequently asked questions

Will 3RV2411-0EA20 drop into a panel that was specified around 3RV2011-0BA20 without rewiring?

Both are S00 frame size breakers with the same 45 mm width and snap-on DIN rail mounting, so the mechanical fit is identical. However, the 3RV2411-0EA20 is a transformer-protection design with a Class 10 trip curve, while the 3RV2011-0BA20 is a standard motor-protective breaker — verify the trip characteristic matches your load before swapping.

What is 3RV2411-0EA20's listed depth (97 mm) on this component line?

The depth is 97 mm, width 45 mm, height 106 mm. The 97 mm depth includes the body and terminal projection; clearance of 50 mm above and below is required for heat dissipation and wiring access.