Skip to main content
Siemens 3RV2411-0EA20-0DA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-0EA20-0DA0 SIRIUS Circuit Breaker, 100 kA at

MPN3RV2411-0EA20-0DA0
Active

Siemens SIRIUS 3RV2411-0EA20-0DA0 circuit breaker, size S00, for transformer protection, 100 kA breaking capacity at 400 V AC, Class 10 trip, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-0EA20-0DA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-0EA20-0DA0 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2411-0EA20-0DA0 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-0EA20-0DA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-0EA20-0DA0 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
3RV2411-0EA20-0DA0 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-0EA20-0DA0 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-0EA20-0DA0 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

It's built to handle the inrush characteristics of a transformer — that's the key difference versus a standard motor-protective breaker. The S00 frame size (45 mm wide, 97 mm deep, 106 mm tall) is the standard compact footprint for this class — fits the same panel cutouts as other S00 breakers.

Trip characteristics and thermal management

The 5.5 W power dissipation at AC in hot operating state is modest; no special ventilation required in a standard IP20 enclosure, but keep it away from other high-dissipation devices if you're packing the rail tight. Rated operating voltage spans 20 to 690 V, covering everything from 24 V control transformers up to 690 V distribution. The 100 kA SCCR at 400 V and above is the headline number for panel builders calculating fault ratings — it's the same 100 kA across 240 V through 690 V, so no derating curve to worry about at higher voltages.

Integration notes

Mounting position is any orientation — no derating for sideways or upside-down mounting. Clearance requirements: 50 mm upwards and downwards, 30 mm to the side, zero forwards or backwards. That 50 mm vertical clearance is important for the arc-quenching path; don't crowd the vents with wire duct or other components. The screwdriver tip spec is 3.0 x 0.5 mm, shaft diameter 3 mm — a standard Pozidriv #1 or flathead will engage the terminal screws properly. Storage and transport range extends to -50 to +80 °C — fine for unheated warehouses or container shipping. The 100,000 mechanical cycles on the main contacts is typical for this class; electrical life depends on the switching frequency (max 15 operations per hour at AC-3 duty) and the actual load current.

Frequently asked questions

What is the breaking capacity of 3RV2411-0EA20-0DA0 at 400 V?

100 kA at 400 V AC, and the same 100 kA rating holds at 240 V, 500 V, and 690 V AC. No derating needed across the operating voltage range for the interrupting rating.

Will 3RV2411-0EA20-0DA0 fit in a panel designed for 3RV2011-0BA20?

Both are S00 frame size (45 mm wide), so the footprint and DIN rail mounting are identical. The 3RV2411 is a transformer-protection breaker; the 3RV2011 is a motor-protective breaker. They share the same mechanical dimensions and terminal layout, so a direct swap is physically possible, but the trip curve is different — verify the application before substituting.

Where can I buy 3RV2411-0EA20-0DA0 and how is it quoted?

This part is sourced through independent industrial distribution channels. Availability and current pricing are confirmed at quote time against an RFQ. Submit a request with your target quantity and delivery window for a firm quote.

MPN
3RV2411-0EA20-0DA0