Siemens 3RV2411-1CA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-1CA15 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV2411-1CA15
Active

Siemens SIRIUS 3RV2411-1CA15, circuit breaker for transformer protection, Trip Class 10, 45 mm width, 100 kA breaking capacity at 400 V, phase failure detection, screw and snap-on mounting on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2411-1CA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-1CA15 — Electrical
ParameterValue
Rated operational current (Ie)2.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2411-1CA15 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current52 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-1CA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-1CA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-1CA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-1CA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-1CA15 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

Transformer-protection breaker with Trip Class 10

Breaking capacity and fuse coordination

Rated breaking capacity hits 100 kA at 400 V and 500 V, dropping to 10 kA at 690 V. For fuse backup coordination, the spec calls for gL/gG fuses: 25 A up to 500 V, 20 A at 690 V. If you're coordinating with a downstream contactor for motor starting, note the maximum operating rate of 15 switching cycles per hour in AC-3 duty.

The 45 mm width (three TE) is standard for SIRIUS breakers — fits alongside contactors and overloads in a motor control center row. That matters when packing multiple breakers in a row — you can butt them front-to-back but need breathing space top and bottom for arc venting and heat rise.

Environmental and wiring specs

That -20 °C floor means it's fine for unheated electrical rooms in temperate climates but not for outdoor enclosures in deep freeze. Main contact terminals accept M3 screws; wire range is 2× (0.5 to 1.5 mm²) solid or stranded, or 2× (0.75 to 2.5 mm²).

Frequently asked questions

What is the breaking capacity of 3RV2411-1CA15 at 400 V?

Rated breaking capacity is 100 kA at 400 V, which means it can safely interrupt faults up to that level without needing upstream devices to clear.

Will 3RV2411-1CA15 drop into a panel specified for 3RV1011-0GA10?

Both mount on 35 mm DIN rail per DIN EN 60715 and share the SIRIUS form factor, so the physical fit is the same. However, the 3RV2411-1CA15 is designed for transformer protection (Trip Class 10) while the 3RV1011-0GA10 is a motor-protective breaker — verify the trip curve matches your load before swapping.

How do I get current pricing and availability for 3RV2411-1CA15?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation at quote time.

MPN
3RV2411-1CA15