Skip to main content
Siemens 3RV2411-1EA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-1EA15 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV2411-1EA15
Active

Siemens SIRIUS, circuit breaker for transformer protection, 3RV2411-1EA15, 100 kA breaking capacity at 400 V, Trip Class 10, 45 mm width, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-1EA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-1EA15 — Electrical
ParameterValue
Rated operational current (Ie)4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2411-1EA15 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Instantaneous short-circuit trip current82 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-1EA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-1EA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-1EA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-1EA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-1EA15 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

What it is and what it does

The Siemens 3RV2411-1EA15 is a SIRIUS circuit breaker designed specifically for transformer protection, with a rated voltage range of 20 to 690 V. It carries a 100 kA breaking capacity at 400 V, 500 V, and 240 V, and a 4 kA rating at 690 V. The Trip Class 10 characteristic means it trips fast enough to protect a transformer winding from sustained overload without nuisance tripping on inrush.

Mounting and integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width and 97 mm depth fit standard panel layouts, and any mounting position is allowed. Phase failure detection is built in, so it will drop the load if one phase is lost — a useful feature for transformer-fed circuits where single-phasing can cause overheating.

Frequently asked questions

What is 3RV2411-1EA15's breaking capacity at 400 V?

It has a 100 kA breaking capacity at 400 V, which means it can safely interrupt fault currents up to that level without upstream damage.

Where can I buy 3RV2411-1EA15?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3RV2411-1EA15 drop into a panel specified around 3RV2021-1FA15?

Both mount on 35 mm DIN rail per DIN EN 60715, so the footprint is the same. However, the 3RV2411-1EA15 is a transformer-protection breaker, while the 3RV2021-1FA15 is for standard motor protection — verify the trip curve and ratings match your load before swapping.

MPN
3RV2411-1EA15