Specifications

3RV2411-1HA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-1HA15 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2411-1HA15 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current163 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-1HA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-1HA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-1HA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-1HA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-1HA15 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

SIRIUS 3RV2411-1HA15 — Transformer-Protection Circuit Breaker

Rated operating voltage spans 20 to 690 V. Short-circuit breaking capacity reaches 100 kA at 400 V and 240 V, 42 kA at 500 V, and 4 kA at 690 V — figures that define the available fault current this breaker can interrupt without upstream coordination failure.

Mounting position is any. Required clearances: 50 mm upward and downward, 30 mm at the side, 0 mm forward and backward — important for panel layout when stacking multiple breakers. Dimensions: 97 mm depth, 45 mm width, 97 mm height.

Protection and Ratings

Phase failure detection is included — the breaker trips on loss of any phase, preventing single-phasing damage to transformers or motors downstream. Horsepower rating: 1 hp at 230 V. Current ratings at various voltages: 8 A at 480 V and 600 V. Short-circuit protection with gL/gG fuses: 50 A at 400 V, 40 A at 500 V, 35 A at 690 V. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 120/125/230 V, 0.15 A at 60 V. Maximum switching frequency in AC-3 duty: 15 operations per hour.

Environmental and Wiring

Storage and transport range: -50 to +80 °C. Terminal capacity: 2 × (0.5 to 1.5 mm²) or 2 × (0.75 to 2.5 mm²) solid or stranded. Main contact screw size: M3.

Lifecycle stage is current production — this is an active catalog item, not phased out or NRND.

Frequently asked questions

Where can I buy 3RV2411-1HA15 and how do I get a price?

The 3RV2411-1HA15 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 3RV2411-1HA15's listed depth and width?

Depth is 97 mm, width is 45 mm, height is 97 mm. The 45 mm width matches the standard SIRIUS 3RV2 single-pole-plus-neutral DIN-rail footprint.

What compliance documentation does this brand provide for 3RV2411-1HA15?

As a Siemens SIRIUS product, the 3RV2411-1HA15 is covered by the manufacturer's standard compliance documentation including RoHS, REACH, and applicable IEC/UL standards. Specific certificates are available on request.

Will 3RV2411-1HA15 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Both are 45 mm wide SIRIUS breakers on the same DIN-rail mounting standard, so the mechanical fit is identical. However, the 3RV2411-1HA15 is designed for transformer protection (3RV1011-1HA10 is a standard motor-protective breaker), so verify the trip curve and setting range match your application before swapping.