Siemens 3RV2411-1JA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2411-1JA10 SIRIUS Circuit Breaker, Transformer Pr

MPN3RV2411-1JA10
Active

Siemens SIRIUS 3RV2411-1JA10 circuit breaker for transformer protection, 100 kA SCCR at 400 V, Trip Class 10, screw-type terminals, 45 mm width, 97 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-1JA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-1JA10 — Electrical
ParameterValue
Rated operational current (Ie)10 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2411-1JA10 — Protection & Tripping
ParameterValue
Overload release setting range7 ... 10 A
Instantaneous short-circuit trip current208 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-1JA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-1JA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-1JA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-1JA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-1JA10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

That means its overload curve and short-circuit release are tuned to handle transformer inrush without nuisance tripping — a detail that matters when you're protecting a dry-type or distribution transformer on a 400 V bus. At 690 V it still clears 4 kA. That SCCR lets this breaker sit upstream of smaller branch devices without worrying about cascading failure during a bolted fault. If your transformer secondary feeds an ungrounded delta or you need GF protection, you'll add an external ground-fault relay or specify a different variant.

Termination & Environment

Main current circuit connections use screw-type terminals, accepting 2× (0.75 to 2.5 mm²) solid or stranded, or 2× 4 mm². The M3 screw is standard for this frame size; torque to the Siemens spec during panel build. That covers most indoor panel environments — no special derating needed for a typical MCC room or cabinet. The fuse backup requirements are specified: gL/gG 50 A at 400 V, 40 A at 500 V, and 40 A at 690 V — coordinate your upstream fuse selection accordingly.