Siemens SIRIUS 3RV2411-4AA15 circuit breaker, for transformer protection, 45 mm width, screw and snap-on 35 mm DIN rail, Class 10 trip, 30 kA at 400 V.

$48.26Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2411-4AA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2411-4AA15 — Electrical
ParameterValue
Rated operational current (Ie)16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2411-4AA15 — Protection & Tripping
ParameterValue
Overload release setting range10 ... 16 A
Instantaneous short-circuit trip current286 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2411-4AA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2411-4AA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2411-4AA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2411-4AA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2411-4AA15 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

The Siemens 3RV2411-4AA15 is a SIRIUS-branded circuit breaker specifically designed for transformer protection. Rated for continuous currents of 16 A at both 480 V and 600 V, this breaker handles the inrush of small to medium transformers without nuisance tripping. Breaking capacity is the key selection parameter here: 100 kA at 240 V, 30 kA at 400 V, 5 kA at 500 V, and 2 kA at 690 V. At 400 V — the most common industrial distribution voltage — the 30 kA SCCR gives you headroom for high-fault panels without cascading upstream breakers.

Mounting position is any orientation, so it works in tight vertical or horizontal panel layouts. Screw terminals accept 2x (0.5–1.5 mm²) or 2x (0.75–2.5 mm²) solid or stranded copper — no special lugs needed. Forced-air cooling clearance: 50 mm above and below, 30 mm to the sides, 0 mm front and back. That keeps the thermal trip within its -20 to +60 °C operating range.

Frequently asked questions

Where can I buy 3RV2411-4AA15 and how do I get a price?

The 3RV2411-4AA15 is available to order through our distribution channel. Submit an RFQ for current pricing and availability — lead time and quantity confirmed at quote time.

What is the breaking capacity of 3RV2411-4AA15 at 400 V?

30 kA at 400 V, which covers most industrial panel fault levels without needing an upstream current-limiting fuse.

Will 3RV2411-4AA15 drop into a panel specified around 3RV2021-4CA25 without rewiring?

Both are 45 mm wide SIRIUS breakers on 35 mm DIN rail, so the footprint is the same. Terminal sizes and wiring range are identical — no rewiring needed for the same conductor sizes.