Skip to main content
Siemens 3RV2421-0JA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2421-0JA10 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2421-0JA10
Active

Siemens SIRIUS 3RV2421-0JA10 circuit breaker for transformer protection, 100 kA breaking capacity at 400 V, Trip Class 10, 45 mm wide, screw and snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2421-0JA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2421-0JA10 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2421-0JA10 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2421-0JA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2421-0JA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
Conductor range, AWG (main contacts)2x (16 ... 12), 2x (14 ... 8)
3RV2421-0JA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2421-0JA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2421-0JA10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

That means the trip curve and thermal memory are tuned for inrush and overload profiles typical of transformers, not motors.

Width is 45 mm, depth 97 mm, height 97 mm — that's a standard three-module footprint on the rail. Clearance: 50 mm above and below, 30 mm to the side, 0 mm forward or backward. Terminals accept 2x (1 to 2.5 mm²) or 2x (2.5 to 10 mm²) solid or stranded, M4 screw-type for the main contacts.

Frequently asked questions

What is the breaking capacity of 3RV2421-0JA10?

100 kA at 400 V, 500 V, and 690 V AC — the same high interrupting rating across the common industrial voltages.

What is 3RV2421-0JA10's width and depth?

Width is 45 mm, depth is 97 mm, height is 97 mm — a standard three-module DIN-rail footprint.

Where can I buy 3RV2421-0JA10?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

Is 3RV2421-0JA10 designed for motor or transformer protection?

Transformer protection — the trip curve and thermal memory are tuned for transformer inrush and overload profiles, not motor starting.

MPN
3RV2421-0JA10