Siemens 3RV2421-4DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2421-4DA10 SIRIUS Circuit Breaker, 25 kA at 400 V

MPN3RV2421-4DA10
Active

Siemens SIRIUS circuit breaker, 3RV2421-4DA10, for transformer protection, 25 kA breaking capacity at 400 V AC, Class 10, phase failure detection, screw and snap-on 35 mm DIN rail mounting.

$52.07Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2421-4DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2421-4DA10 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV2421-4DA10 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Instantaneous short-circuit trip current400 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2421-4DA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2421-4DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
Conductor range, AWG (main contacts)2x (16 ... 12), 2x (14 ... 8)
3RV2421-4DA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2421-4DA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2421-4DA10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

Transformer-protection circuit breaker, SIRIUS series

The Siemens 3RV2421-4DA10 is a SIRIUS-branded circuit breaker specifically designed for transformer protection, not general motor or feeder duty. At 240 V the interrupting rating rises to 100 kA, reflecting the higher available fault current typical in North American 240 V distribution.

Depth is 97 mm; forwards clearance is 0 mm. Screw-type terminals on the main current circuit accept 2×(1…2.5 mm²) or 2×(2.5…10 mm²) solid or stranded copper — sized for transformer primary wiring up to about 10 mm².

Rated ultimate short-circuit breaking capacity varies by voltage: 100 kA at 240 V, 25 kA at 400 V, 5 kA at 500 V, and 2 kA at 690 V. The 25 kA at 400 V is the figure most relevant for European 400 V three-phase panels; the 2 kA at 690 V means it is not intended for 690 V industrial mains without upstream current-limiting fuses. Back-up fuse recommendations are listed: gL/gG 63 A at 400 V, 50 A at 500 V and 690 V.

Frequently asked questions

Does the 3RV2421-4DA10 detect phase failure?

Yes, phase failure detection is built in. The breaker will open on a lost phase to prevent single-phase transformer heating.