Siemens 3RV2431-4JA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2431-4JA10 SIRIUS Circuit Breaker, 30 kA at 400 V

MPN3RV2431-4JA10
Active

Siemens SIRIUS 3RV2431-4JA10 circuit breaker for transformer protection, CLASS 10 trip, 30 kA interrupting capacity at 400 VAC, screw terminals, 55 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2431-4JA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2431-4JA10 — Electrical
ParameterValue
Rated operational current (Ie)65 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)26 W
Power loss, per pole (AC, hot)8.7 W
3RV2431-4JA10 — Protection & Tripping
ParameterValue
Overload release setting range54 ... 65 A
Instantaneous short-circuit trip current1 040 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)65 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2431-4JA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h
3RV2431-4JA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 1)
3RV2431-4JA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2431-4JA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2431-4JA10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection

Product details

The Siemens 3RV2431-4JA10 is a SIRIUS-brand circuit breaker specifically designed for transformer protection. Interrupting capacity is 100 kA at 240 VAC and 30 kA at 400 VAC, per the datasheet. If one phase drops out, the breaker trips — a critical feature for transformer primary protection where single-phasing can overheat the remaining windings. No ground fault detection on this variant.

Depth is 149 mm, height 140 mm. Mounting position is any orientation. That 50 mm vertical clearance is for arc-chamber venting — don't crowd it against cable ducts or panel walls. Main circuit terminals are screw-type, accepting 2× (1 to 35 mm²) or 1× (1 to 50 mm²) solid or stranded copper. Terminal screw size is M6. Strip length and torque values per the installation instructions — the 50 mm² single-conductor capacity is useful for feeding a transformer primary with a single large cable.

Environmental and electrical ratings

Rated operational voltage spans 20 to 690 V. Motor-switching capability at AC-3 duty is 15 operations per hour maximum. That's a switching rate, not a continuous current rating — the breaker is sized for transformer primary protection, not frequent motor starting. Power ratings at various voltages: 18.5 kW at 230 V, 25 hp at 220/230 V, 50 hp at 460/480 V, 60 hp at 575/600 V. Current ratings: 65 A at 480 V, 62 A at 600 V.

Lifecycle status is listed as current production. This is an active catalog item in the SIRIUS range, not a phase-out or NRND part.

Frequently asked questions

What is the interrupting capacity of 3RV2431-4JA10 at 400 V?

30 kA at 400 VAC. At 240 VAC it is 100 kA. The 30 kA figure is the one to use for panel SCCR coordination at 400 V.

What is the trip class of this circuit breaker?

CLASS 10. It trips within 10 seconds at 7.2× the thermal setting, designed for transformer inrush tolerance.

What are the mounting dimensions for 3RV2431-4JA10?

Width 55 mm, height 140 mm, depth 149 mm. It snaps onto 35 mm DIN rail per DIN EN 60715. Clearance: 50 mm above and below, 10 mm to the side, zero forward or backward.

Does 3RV2431-4JA10 have phase failure detection?

Yes, phase failure detection is built in. No ground fault detection on this variant.

Where can I buy 3RV2431-4JA10 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.