Siemens 3RV2711-0JD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2711-0JD10 SIRIUS Circuit Breaker, S00, 100 kA SC

MPN3RV2711-0JD10
Active

Siemens SIRIUS 3RV2711-0JD10 circuit breaker, size S00, 100 kA interrupting capacity at 240-690 V AC, screw and snap-on 35 mm DIN rail mount, UL 489 system protection design.

$69.85Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2711-0JD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2711-0JD10 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2711-0JD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current13 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2711-0JD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2711-0JD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2711-0JD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2711-0JD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2711-0JD10 — Specifications
ParameterValue
Design Of The ProductFor system protection according to UL 489/CSA C22.2 No. 5

Product details

The Siemens SIRIUS 3RV2711-0JD10 is a circuit breaker in the S00 frame size, designed for system protection per UL 489 and CSA C22.2 No. 5. It's the part that sits upstream of a motor starter or downstream of a feeder breaker, providing short-circuit and overload protection for the branch circuit.

Any mounting position is permitted, which simplifies layout when the panel is tight on vertical clearance. That last one means you can butt it against a panel door or cover without derating.

Rated operational voltage spans 20 to 690 V AC. The 100 kA interrupting capacity holds across the full range — 240 V, 400 V, 500 V, 690 V — which is unusual; many breakers derate at higher voltages. That flat SCCR curve simplifies coordination studies: one number for the whole voltage band. Maximum switching frequency under AC-3 duty (motor starting) is 15 operations per hour — fine for a pump or conveyor start cycle, not for a rapid-reversing application.

Frequently asked questions

What is the interrupting capacity of 3RV2711-0JD10?

100 kA at 240 V through 690 V AC — the rating holds flat across the entire voltage range, which is a strong coordination advantage.

What are the mounting dimensions for 3RV2711-0JD10?

45 mm wide, 144 mm tall, 97 mm deep. Mounts on 35 mm DIN rail via screw and snap-on. Requires 70 mm clearance above and below, 30 mm to the side, zero forward clearance.

Will 3RV2711-0JD10 drop into a panel designed for 3RV2011-0AA10?

Both are S00 frame size on 35 mm DIN rail, so the mechanical footprint and mounting are identical. The difference is in the interrupting rating and protection curve — verify coordination before swapping.

Where can I buy 3RV2711-0JD10 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV2711-0JD10