Skip to main content
Siemens 3RV2711-0KD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2711-0KD10 SIRIUS Circuit Breaker, S00, 100 kA at

MPN3RV2711-0KD10
Active

Siemens SIRIUS, circuit breaker, size S00, 100 kA at 400 V AC, screw and snap-on 35 mm DIN rail, UL 489/CSA design.

$69.85Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2711-0KD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2711-0KD10 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2711-0KD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current16 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2711-0KD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2711-0KD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2711-0KD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2711-0KD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2711-0KD10 — Specifications
ParameterValue
Design Of The ProductFor system protection according to UL 489/CSA C22.2 No. 5

Product details

The Siemens 3RV2711-0KD10 is a SIRIUS-brand circuit breaker in size S00, designed for system protection per UL 489 and CSA C22.2 No. 5. Rated voltage spans 20 to 690 V, covering most low-voltage industrial supplies. The motor rating at 230 V is 0.2 kW — a light load, typical for small pumps or fans on a sub-feed.

Panel fit and wiring constraints

Dimensions are 97 mm deep, 45 mm wide, 144 mm tall. That 0 mm forwards means it can sit flush against a gland plate or enclosure wall without airflow worry — but the 70 mm top/bottom gap is mandatory for arc-quenching and terminal access. Use a Pozidriv size 2 tip or a 5–6 mm diameter screwdriver shaft. Torque to M4 on the main contacts — no special crimp tool needed for the wire range.

Environmental and operating limits

Maximum switching frequency in AC-3 duty is 15 operations per hour — not a cycling application; this is a protection device, not a contactor for frequent starts.

Frequently asked questions

Will the 3RV2711-0KD10 drop into a panel specified for the 3RV2011-0AA10?

Both are size S00 circuit breakers on 35 mm DIN rail with screw terminals, so the physical footprint and mounting are identical. The 3RV2711-0KD10 is designed for system protection per UL 489/CSA, while the 3RV2011-0AA10 may have different trip characteristics or approvals — verify the protection curve and breaking capacity against your BOM before swapping.

MPN
3RV2711-0KD10