Siemens 3RV2711-1AD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2711-1AD10 SIRIUS Circuit Breaker, Size S00, 100

MPN3RV2711-1AD10
Active

Siemens SIRIUS 3RV2711-1AD10 circuit breaker, Size S00, for system protection per UL 489, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV2711-1AD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2711-1AD10 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2711-1AD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current21 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2711-1AD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2711-1AD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2711-1AD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2711-1AD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2711-1AD10 — Specifications
ParameterValue
Design Of The ProductFor system protection according to UL 489/CSA C22.2 No. 5

Product details

The Siemens 3RV2711-1AD10 is a SIRIUS-brand circuit breaker in the Size S00 frame, designed for system protection per UL 489 and CSA C22.2 No. 5. The part is rated for a 0.3 kW motor at 230 V — a modest load, consistent with the Size S00 frame's typical role protecting smaller motors, control transformers, or branch circuits in a panel.

The screw terminals use M4 threads and require a Pozidriv size 2 screwdriver tip with a 5–6 mm shaft diameter. These are standard panel-building specs — no special tooling needed.

Fuse backup coordination

When the available fault current exceeds the breaker's interrupting rating, or when selective coordination is required upstream, the 3RV2711-1AD10 specifies maximum backup fuse ratings: 20 A gL/gG at 500 V, and 16 A gL/gG at 690 V. These are the fuse sizes that, when placed ahead of the breaker, ensure the breaker still clears a fault within its rated limits.

The part carries no ground-fault or phase-failure detection — it is a straight thermal-magnetic or electronic motor-protective circuit breaker. If your application requires those functions, you would need a different variant in the SIRIUS family or an external monitoring relay.

Frequently asked questions

What is the breaking capacity of 3RV2711-1AD10 at 400 V?

100 kA at 400 V AC. The same 100 kA rating applies at 240 V, 500 V, and 690 V AC.

Will 3RV2711-1AD10 drop into a panel specified around 3RV2011-0AA10 without rewiring?

Both are Size S00 frame breakers on a 35 mm DIN rail, so the footprint and mounting are compatible. However, the 3RV2711-1AD10 is designed for UL 489 system protection, while the 3RV2011-0AA10 is a motor-protective breaker per IEC 60947. The terminal sizes and wiring capacity (1–10 mm²) are the same, so rewiring is not required — but verify the interrupting rating and protection function match your panel's design intent.

Where can I buy 3RV2711-1AD10 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for 3RV2711-1AD10?

The part is designed for system protection per UL 489 and CSA C22.2 No. 5. Siemens typically provides a Declaration of Conformity (CE), RoHS, and REACH documentation upon request through the standard compliance portal.

MPN
3RV2711-1AD10