Siemens 3RV2711-4AD10-0RT0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2711-4AD10-0RT0 Circuit Breaker, Size S00, 30 kA

MPN3RV2711-4AD10-0RT0

Siemens SIRIUS 3RV2 circuit breaker, size S00, screw terminals, 20...690 V rated, 30 kA breaking capacity at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2711-4AD10-0RT0 — Identification
ParameterValue
Frame sizeS00
3RV2711-4AD10-0RT0 — Electrical
ParameterValue
Rated operational current (Ie)16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2711-4AD10-0RT0 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current208 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2711-4AD10-0RT0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2711-4AD10-0RT0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
3RV2711-4AD10-0RT0 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2711-4AD10-0RT0 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Product details

The Siemens 3RV2711-4AD10-0RT0 is a size S00 circuit breaker from the SIRIUS 3RV2 family, rated for 20... 690 V and delivering a 30 kA breaking capacity at 400 V AC. At 240 V AC it handles 100 kA, at 500 V AC 10 kA, and at 690 V AC 4 kA. Rated for motor duty at AC-3 up to 690 V, with a maximum of 15 operating cycles per hour. The main contacts are rated for 100 000 typical mechanical operations. Power loss in hot operating state is 9.25 W at AC.

Mounting and clearance — panel fit check

Dimensions are 45 mm wide, 144 mm high, 97 mm deep. Clearance requirements: 70 mm upwards, 70 mm downwards, 30 mm at the side, 0 mm forwards and backwards. That zero forward clearance means no extra deadfront space needed — the breaker can sit flush against a panel door or cover. Main contact screws are M4; use a Pozidriv size 2 tip with a 5 to 6 mm diameter shaft.

Fuse coordination and operating conditions

Back-up fuse ratings are specified per voltage: gG 80 A at 240 V, gG 63 A at 400 V, gG 50 A at 500 V, gG 40 A at 690 V. This governs the upstream fuse size for selective coordination — match the voltage to your line-to-line supply. No ground fault or phase failure detection built in — that's a separate add-on module if your application requires it.

Frequently asked questions

What is the depth of 3RV2711-4AD10-0RT0?

The depth is 97 mm, with 0 mm forward clearance required — it can sit flush against a panel door or cover.

What is the width of 3RV2711-4AD10-0RT0?

The width is 45 mm, fitting a standard 45 mm DIN-rail slot. Side clearance required is 30 mm.

MPN