Siemens 3RV2811-0AD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-0AD10 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2811-0AD10
Active

Siemens SIRIUS circuit breaker, 3RV2811-0AD10, Size S00, for transformer protection per UL 489/CSA C22.2 No.5, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2811-0AD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-0AD10 — Electrical
ParameterValue
Rated operational current (Ie)0.16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2811-0AD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current3.3 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-0AD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2811-0AD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-0AD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2811-0AD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-0AD10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

The Siemens 3RV2811-0AD10 is a SIRIUS circuit breaker specifically designed for transformer protection, complying with UL 489 and CSA C22.2 No.5. Rated for 20 to 690 V, this breaker delivers a consistent 100 kA breaking capacity across the 240 V to 690 V AC range. Power dissipation at 5.5 W in hot operating state is modest — no special ventilation needed in a standard enclosure.

Panel fit and clearances

That zero forward/backward clearance means you can butt it against a back panel or enclosure door without derating — handy for tight enclosures. Terminals accept 1 to 10 mm² solid or stranded wire, up to 2x 10 mm² — screw-type terminals with M4 screws for the main contacts. Use a Pozidriv size 2 tip or a 5-6 mm diameter screwdriver shaft.

Mechanical endurance and switching frequency

Main contacts are rated for 100,000 typical mechanical operations. Maximum switching frequency at AC-3 and AC-3e duty is 15 operations per hour.

Frequently asked questions

Will 3RV2811-0AD10 drop into a panel specified around 3RV2011-0AA10 without rewiring?

Both are Size S00 breakers on 35 mm DIN rail with similar dimensions, so the mechanical fit is the same. The 3RV2811-0AD10 is designed for transformer protection per UL 489/CSA C22.2 No.5, while the 3RV2011 series covers motor and general applications — check your application's coordination study before swapping.

MPN
3RV2811-0AD10