Siemens 3RV2811-0ED10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-0ED10 SIRIUS Circuit Breaker, 100 kA at 400

MPN3RV2811-0ED10
Active

Siemens SIRIUS circuit breaker, size S00, 3RV2811-0ED10, for transformer protection per UL 489/CSA C22.2 No.5, 100 kA breaking capacity at 400 V AC, 45 mm wide, screw and snap-on DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2811-0ED10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-0ED10 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2811-0ED10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current8.2 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-0ED10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2811-0ED10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-0ED10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2811-0ED10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-0ED10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

Transformer-protection circuit breaker, size S00

The Siemens 3RV2811-0ED10 is a SIRIUS circuit breaker in size S00, designed specifically for transformer protection and listed to UL 489 / CSA C22.2 No.5. That UL 489 listing means it qualifies as a branch-circuit protective device in North American panels — not just a motor-protective breaker — so it can serve as the primary overcurrent protection for a control transformer secondary. Rated breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC — a flat 100 kA across the common industrial voltages. That eliminates the need to check a derating curve when the supply voltage changes within a panel; the SCCR stays at 100 kA regardless of whether the line is 400 V or 690 V.

Width is 45 mm, depth 97 mm, height 144 mm. Clearance requirements: 70 mm above and below, 30 mm to the sides, 0 mm forward and backward. The zero forward/backward clearance means the breaker can be butted directly against the back panel or enclosure door without derating — useful when gland-plate depth is tight.

Termination and environment

Main contacts use M4 screw-type terminals, accepting 1 to 10 mm² solid or stranded, up to 2 × 10 mm². Screwdriver shaft diameter 5 to 6 mm, Pozidriv size 2 tip — standard panel-building tooling. The wide storage range covers unheated warehouses and container shipping without special handling.

Frequently asked questions

What compliance documentation does Siemens provide for this circuit breaker?

The breaker is designed for transformer protection per UL 489 and CSA C22.2 No.5, which are the governing standards for branch-circuit protection in North America. Standard Siemens documentation includes the UL/CSA listing mark on the device label.

Will the 3RV2811-0ED10 drop into a panel specified around the 3RV2011-0AA10?

Both are size S00 breakers on the same 45 mm footprint with screw and snap-on DIN-rail mounting, so the mechanical fit is identical. The 3RV2811-0ED10 is specifically designed for transformer protection per UL 489, while the 3RV2011-0AA10 is a standard motor-protective breaker — the functional difference is the UL listing and the intended application, not the panel cutout.