Skip to main content
Siemens 3RV2811-0FD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-0FD10 SIRIUS Circuit Breaker, 100 kA SCCR, S

MPN3RV2811-0FD10
Active

Siemens SIRIUS circuit breaker, order code 3RV2811-0FD10, size S00, 100 kA interrupting capacity at 240-690 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2811-0FD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-0FD10 — Electrical
ParameterValue
Rated operational current (Ie)0.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2811-0FD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current10 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-0FD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2811-0FD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-0FD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2811-0FD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-0FD10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

Transformer-protection circuit breaker, 100 kA SCCR

The Siemens 3RV2811-0FD10 is a SIRIUS-brand circuit breaker specifically designed for transformer protection, complying with UL 489 and CSA C22.2 No. 5. Rated operational voltage spans 20 to 690 V, covering most global low-voltage industrial supplies. That matters for thermal derating and arc-flash containment in a crowded panel — maintain those gaps to keep the 100 kA rating valid.

No official successor has been issued; the SIRIUS 3RV2 family is the established platform. Check terminal ratings: this unit uses M4 main-contact screws and accepts 1–10 mm² solid/stranded.

Integration notes

Screw terminals accept Pozidriv size 2 or a 5–6 mm diameter screwdriver shaft. No ground-fault or phase-failure detection built in — this is a straightforward magnetic/thermal breaker for transformer primary protection. The 100 kA SCCR holds at 240, 400, 500, and 690 V AC — no voltage-dependent derating on the interrupting capacity within that band.

Frequently asked questions

Will 3RV2811-0FD10 drop into a panel designed for 3RV2011-0AA10?

Both are S00 frame size, 45 mm wide, and mount on 35 mm DIN rail, so the mechanical footprint is identical. However, the 3RV2811-0FD10 is a transformer-protection breaker (UL 489), while the 3RV2011-0AA10 is a standard motor-protective breaker — verify the trip curve and interrupting rating match your application before substitution.

MPN
3RV2811-0FD10