Siemens 3RV2811-0HD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-0HD10 SIRIUS Circuit Breaker, 100 kA, S00

MPN3RV2811-0HD10
Active

Siemens SIRIUS, circuit breaker, size S00, 3RV2811-0HD10, 100 kA breaking capacity at 400 V AC, for transformer protection per UL 489, screw and snap-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2811-0HD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-0HD10 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2811-0HD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current16 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-0HD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2811-0HD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-0HD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2811-0HD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-0HD10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

The Siemens 3RV2811-0HD10 is a SIRIUS circuit breaker in size S00, designed specifically for transformer protection and compliant with UL 489 and CSA C22.2 No.5. It delivers 100 kA breaking capacity at 400 V AC — the same rating holds at 240 V, 500 V, and 690 V AC, so you get consistent fault-interrupt performance across common industrial voltages without derating the breaker.

The S00 footprint — 45 mm wide, 144 mm tall, 97 mm deep — fits standard sub-distribution boards and motor starter combos. Any mounting position works, which simplifies layout in tight enclosures.

Rated operational voltage spans 20 to 690 V, covering low-voltage control circuits through 690 V distribution. At 230 V it carries a 0.1 kW motor rating under AC-3 duty, so it's sized for small motor branches, not main feeders. The gG 6 A fuse backup at 690 V tells you the coordination curve: upstream fuse limits let-through energy for the breaker's own protection.

Main contact screws are M4; use a Pozidriv size 2 tip with a 5–6 mm shaft diameter. Strip and torque per standard practice — the spring-cage alternative isn't offered here.

Environmental limits

No ground-fault or phase-failure detection built in — those functions live in separate monitoring relays or the upstream protection.

Frequently asked questions

Where can I buy 3RV2811-0HD10 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What are the key dimensions of 3RV2811-0HD10?

Width 45 mm, height 144 mm, depth 97 mm. It requires 70 mm clearance above and below, 30 mm at the sides, and zero forward clearance.

What breaking capacity does 3RV2811-0HD10 offer?

100 kA at 240 V, 400 V, 500 V, and 690 V AC — consistent fault interruption across the voltage range without derating.

Is 3RV2811-0HD10 designed for transformer protection?

Yes, the design is specifically for transformer protection per UL 489 and CSA C22.2 No.5. It is not a general-purpose motor circuit breaker — use it where inrush and overload characteristics match transformer primaries.

MPN
3RV2811-0HD10