Siemens 3RV2811-0JD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-0JD10 SIRIUS Circuit Breaker, 100 kA SCCR

MPN3RV2811-0JD10
Active

Siemens SIRIUS circuit breaker, size S00, 3RV2811-0JD10, 100 kA SCCR at 400 V, screw and snap-on 35 mm DIN rail, UL 489 transformer protection design.

$74.93Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV2811-0JD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-0JD10 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2811-0JD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current21 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-0JD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2811-0JD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-0JD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2811-0JD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-0JD10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

The Siemens 3RV2811-0JD10 is a SIRIUS circuit breaker in size S00, designed specifically for transformer protection per UL 489 and CSA C22.2 No.5. That UL 489 listing means it's certified as a branch-circuit protective device — not just a supplementary protector — so it can serve as the sole overcurrent protection on a transformer primary, saving a separate fuse or breaker downstream.

Interrupting capacity — the number that governs the fault study

Rated at 100 kA at 240 V, 400 V, 500 V, and 690 V AC. That's a flat 100 kA SCCR across the common industrial voltage range. The 100 kA figure holds for both the general-purpose and AC-3 motor switching duty, so it covers mixed loads on the same branch.

The screwdriver shaft needs a 5 to 6 mm diameter, Pozidriv size 2 tip. Mounting position is any orientation — no derating for sideways or inverted installation. That 97 mm depth means it sits flush with most 100 mm deep enclosures; no need for a deeper gland plate.

Environmental limits and switching frequency

The storage range is wider — that's the handling limit, not the running limit. That's fine for a transformer primary or a pump start, but not for a rapid-cycling application like a press or a conveyor index.

Frequently asked questions

How do I get current pricing and availability for 3RV2811-0JD10?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

Will 3RV2811-0JD10 drop into a panel specified around 3RV2021-0HA15 without rewiring?

Both are SIRIUS size S00 breakers on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. The 3RV2811-0JD10 is designed for UL 489 transformer protection, while the 3RV2021-0HA15 is a general-purpose motor-protective breaker — the terminal layout and wiring rules are the same, but verify the trip curve matches your load before swapping.

What compliance documentation does Siemens provide for 3RV2811-0JD10?

The breaker carries UL 489 and CSA C22.2 No.5 certification for transformer protection. Standard Siemens documentation includes CE declaration of conformity and RoHS/REACH compliance statements available on request.