Skip to main content
Siemens 3RV2811-1JD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-1JD10 SIRIUS Circuit Breaker, S00, 100kA @ 4

MPN3RV2811-1JD10
Active

Siemens SIRIUS 3RV2811-1JD10, size S00 circuit breaker, 100 kA interrupting at 400 V AC, screw/snap-on 35 mm DIN rail, UL 489 transformer protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2811-1JD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-1JD10 — Electrical
ParameterValue
Rated operational current (Ie)10 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2811-1JD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current208 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-1JD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2811-1JD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-1JD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2811-1JD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-1JD10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

SIRIUS S00 — transformer-protection breaker with 100 kA interrupting capacity

The Siemens 3RV2811-1JD10 is a SIRIUS-branded circuit breaker in size S00, designed specifically for transformer protection per UL 489 and CSA C22.2 No.5. It delivers 100 kA interrupting capacity at 400 V AC (also 240 V AC), dropping to 42 kA at 500 V and 4 kA at 690 V — meaning it can clear a hard fault on a 400 V distribution bus without cascading upstream breakers. The 2.2 kW rating at 230 V gives a quick motor-load reference for panel builders. The screw-type main terminals accept 1 to 10 mm² solid/stranded, up to 2x 10 mm², with an M4 contact screw.

Integration — DIN-rail fit and clearances

The Pozidriv size 2 screwdriver tip (5-6 mm shaft) is standard for terminal work.

Frequently asked questions

Where can I buy 3RV2811-1JD10 and how do I get a price?

Sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

Will 3RV2811-1JD10 drop into a panel specified around 3RV2023-4DA10 without rewiring?

Both are SIRIUS size S00 breakers on 35 mm DIN rail, so the mechanical footprint and rail mounting are the same. However, the 3RV2811-1JD10 is a UL 489 transformer-protection variant with 100 kA interrupting at 400 V, while the 3RV2023-4DA10 is a different family — verify the terminal layout and protective settings against your wiring diagram before swapping.

What is 3RV2811-1JD10's listed depth (97 mm) on this component line?

Depth is 97 mm, width 45 mm, height 144 mm. Required clearances: 70 mm above/below, 30 mm sides, zero forward/backward.

What compliance documentation does this brand provide for 3RV2811-1JD10 (RoHS, REACH, UL, IEC)?

The breaker is designed for UL 489 and CSA C22.2 No.5 transformer protection. The SIRIUS brand typically provides RoHS and REACH declarations; consult the product documentation for the specific certificates.