Siemens 3RV2811-4AD10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2811-4AD10 SIRIUS Circuit Breaker, 100 kA at 240

MPN3RV2811-4AD10
Active

Siemens SIRIUS 3RV2811-4AD10 circuit breaker for transformer protection, size S00, 100 kA breaking capacity at 240 V AC, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2811-4AD10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2811-4AD10 — Electrical
ParameterValue
Rated operational current (Ie)15 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2811-4AD10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current286 A
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionNo
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2811-4AD10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV2811-4AD10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded1 ... 10 mm², max. 2x 10 mm²
Conductor cross-section, finely stranded with ferrule1 ... 16 mm², max. 6 + 16 mm²
Conductor range, AWG (main contacts)2x (14 ... 10)
3RV2811-4AD10 — Mechanical
ParameterValue
Height144 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2811-4AD10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2811-4AD10 — Specifications
ParameterValue
Design Of The ProductFor transformer protection according to UL 489/CSA C22.2 No.5

Product details

The Siemens 3RV2811-4AD10 is a SIRIUS-branded circuit breaker specifically designed for transformer protection per UL 489 and CSA C22.2 No.5. It occupies the S00 frame size — 45 mm wide, 97 mm deep, 144 mm tall — and mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. Breaking capacity is the headline here: 100 kA at 240 V AC, 55 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC.

The screwdriver shaft should be 5 to 6 mm diameter. Main contact screws are M4. Clearance requirements: 70 mm upwards and downwards, 30 mm at the sides, 0 mm forwards and backwards — so it can sit flush against the back panel or a busbar, but needs breathing room above and below for arc venting and cable entry.

Environmental limits

Rated operating voltage spans 20 to 690 V. No ground-fault or phase-failure detection built in — that's external if needed.

Frequently asked questions

What is the breaking capacity of 3RV2811-4AD10 at 400 V?

At 400 V AC the breaking capacity is 55 kA, and at 240 V AC it is 100 kA.

Where can I buy 3RV2811-4AD10?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Does 3RV2811-4AD10 include ground-fault or phase-failure protection?

No, ground-fault detection and phase-failure detection are both listed as 'No' — those functions must be handled externally if required.