Skip to main content
Siemens 3RV2902-1DS0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2902-1DS0 Shunt Release, 500 V AC, for 3RV2

MPN3RV2902-1DS0
Active

Siemens SIRIUS shunt release 3RV2902-1DS0, 500 V AC 50/60 Hz, screw-type terminals, for 3RV2 motor circuit breakers sizes S00, S0, S2, S3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2902-1DS0 — Identification
ParameterValue
SeriesSIRIUS
Product designationshunt release
Frame sizeS00, S0, S2, S3
3RV2902-1DS0 — Electrical
ParameterValue
Rated voltage690 V
3RV2902-1DS0 — Mechanical
ParameterValue
Height90 mm
Width19 mm
Depth68 mm
Mounting methodsnap-on mounting
3RV2902-1DS0 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C

Product details

The Siemens SIRIUS 3RV2902-1DS0 is a shunt release — a remote-trip accessory for 3RV2 motor circuit breakers. It sits on the breaker's left side via snap-on mounting, adding a control-voltage-operated trip coil that lets a PLC, E-stop circuit, or remote pushbutton open the breaker without anyone walking to the panel. The control supply is AC only, 500 V at 50/60 Hz. It's rated for 100% ON period at 500 V AC, and also listed for a 5-second ON period at 500 V DC — meaning it can be pulsed from a DC source for a short interval, but continuous DC hold is not supported. Minimum closing power is 13 W DC, so verify your control transformer can deliver that inrush. Connection is via screw-type terminals on the auxiliary/control circuit. The unit breaks the circuit in a maximum of 20 ms from coil energization — fast enough for most emergency-off and interlock sequences.

Snap-on mounting onto the 3RV2 breaker frame — no tools needed. The 19 mm width means it adds one modular unit to the breaker's footprint. Overall dimensions are 19 x 90 x 68 mm (W x H x D). Depth of 68 mm is the same as the base breaker; no extra panel depth required. Compatible with 3RV2 breakers in sizes S00, S0, S2, and S3 — that covers the full SIRIUS 3RV2 motor-protective circuit-breaker range from 0.1 A up to 100 A. If your panel has a 3RV2, this shunt release clips on.

Insulation rated at 690 V AC with pollution degree 3.

Frequently asked questions

What is the control voltage for 3RV2902-1DS0?

500 V AC at 50/60 Hz for continuous duty. It also supports 500 V DC for a 5-second ON period — use it for pulsed DC trip, not continuous DC hold.

Where can I buy 3RV2902-1DS0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send an RFQ for your quantity.

MPN
3RV2902-1DS0