Skip to main content
Siemens 3RV2917-5D — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2917-5D SIRIUS Terminal Block, 32 A, 500 V, Sprin

MPN3RV2917-5D
Active

Siemens SIRIUS 3RV2917-5D terminal block, for power outlet, spring-loaded terminals, 32 A ampacity, 500 V insulation, 1.5–6 mm² solid/stranded, 50.2 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2917-5D — Identification
ParameterValue
SeriesSIRIUS
Product designationTerminal block
3RV2917-5D — Electrical
ParameterValue
Rated insulation voltage (Ui), pollution degree 3500 V
3RV2917-5D — Connections
ParameterValue
Conductor cross-section, solid / stranded1.5 ... 6 mm²
Conductor cross-section, finely stranded with ferrule1.5 ... 4 mm²
Conductor range, AWG (main contacts)1x (15 ... 10)
3RV2917-5D — Mechanical
ParameterValue
Height34.5 mm
Width40.2 mm
Depth50.2 mm
3RV2917-5D — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
3RV2917-5D — Specifications
ParameterValue
Design Of The Productfor power outlet

Product details

The Siemens 3RV2917-5D is a SIRIUS terminal block designed for power-outfeed applications and for connecting 3-phase busbars in a motor-starter or distribution assembly. Rated for a maximum ampacity of 32 A with an insulation voltage of 500 V at pollution degree 3, it uses spring-loaded terminals that accept 1.5 to 6 mm² solid or stranded copper. The 50.2 mm depth and 40.2 mm width let it fit into the standard DIN-rail footprint alongside SIRIUS contactors and circuit breakers — no extra panel space needed beyond what the rail already occupies.

Spring-cage terminals accept 1.5–6 mm² solid or stranded, or 1.5–4 mm² finely stranded with ferrule. The 32 A rating matches the typical infeed capacity of a SIRIUS S00 or S0 motor starter feeder. The 50.2 mm depth leaves clearance in standard 80 mm or 100 mm deep enclosures.

RoHS compliant with substance prohibition date 10/01/2009. The insulation voltage of 500 V at pollution degree 3 covers standard 400 VAC industrial panels with margin.

Frequently asked questions

Where can I buy 3RV2917-5D and get a price?

The 3RV2917-5D is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What conductor sizes does the 3RV2917-5D accept?

Spring-loaded terminals accept 1.5–6 mm² solid or stranded, 1.5–4 mm² finely stranded with ferrule, and AWG 15–10 for the main circuit.

What is the 3RV2917-5D's depth?

The depth is 50.2 mm, with a width of 40.2 mm and height of 34.5 mm.

MPN