Siemens 3RV5031-4AA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV5031-4AA10 SIRIUS Motor Protection Circuit Breake

MPN3RV5031-4AA10

Siemens SIRIUS, motor protection circuit breaker, 3RV5031-4AA10, 3-pole, 16 A rated current, Class 10 trip, 690 V AC, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV5031-4AA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV5031-4AA10 — Electrical
ParameterValue
Rated operational current (Ie)16 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV5031-4AA10 — Protection & Tripping
ParameterValue
Overload release setting range11 ... 16 A
Instantaneous short-circuit trip current208 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV5031-4AA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.75 ... 25 mm²), 1x (0.75 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 1x (0.75 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV5031-4AA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV5031-4AA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV5031-4AA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV5031-4AA10 is a SIRIUS motor protection circuit breaker, size S2, with a 16 A rated operational current and a Class 10 thermal overload trip. The 3-pole breaker uses screw-type box terminals and mounts on a 35 mm DIN rail per EN 50022 — snap-on or screw fastening, any position. Power loss runs about 12 W total at rated load.

The 16 A rated current at AC-3 (400 V) is the motor-switching figure that governs real use — it matches a typical 7.5 kW induction motor on a 400 V line. The Class 10 trip characteristic means the thermal overload element will trip within 10 seconds at 7.2× rated current, which protects standard squirrel-cage motors during start-up without nuisance tripping on normal acceleration. The magnetic short-circuit release handles fault clearing independently. The 690 V rated insulation voltage gives headroom for 480 V or 600 V class systems.

The S2 frame is 55 mm wide, 140 mm high, 149 mm deep.

Frequently asked questions

Will 3RV5031-4AA10 drop into a panel specified around 3RV5341-4LC10?

Both are SIRIUS S2 frame motor protection breakers with the same DIN rail footprint and terminal arrangement, so mechanical fit is identical. The electrical ratings differ — verify the 16 A / Class 10 profile matches your load before swapping.